Issue
A customer would like to create a new login for ION Setup 3.0 software

Product Line
ION Setup 3.0

Environment
User authentication

Cause
A new login information (username/password) needs to be created to be used on ION Setup 3.0 software.

Resolution
1) Login to ION Setup with a supervisor account
2) Navigate to Tools -> Options and open the "Security" tab
3) Choose which Group you would like to add the new user to.
4) Click "Add..." button
5) Enter the new username in "Log on" field
6) Enter password under "New Password" field. Re-enter that password again in "Confirm Password" field
Note: Your password strength will be indicated under password strength field.
7) Click "OK" on security information windows to create the new user. The newly created user will be listed in users' list under security tab.
8) Click "OK" to confirm changes and close "Options" windows.
9) You can log out of ION Setup 3.0 software now and use the newly created user.

Schneider Electric Česká republika

Zjistěte více
Řada:
Zjistěte více
Řada:
  • Dokumentace k produktům
  • Software ke stažení
  • Nástroj pro výběr produktů
  • Hledání náhrady za produkty
  • Centrum nápovědy a kontakty
  • Najít naše pobočky
  • Získejte nabídku
  • Kde koupit
  • Komunita Schneider Electric
  • Kariéra
  • Profil společnosti
  • Nahlásit nevhodné chování
  • Přístupnost
  • Newsroom
  • Investoři
  • EcoStruxure
  • Vyhledávání pracovních míst
  • Blog
  • Zásady ochrany osobních údajů
  • Oznámení o souborech cookie
  • Podmínky použití
  • Změnit nastavení souborů cookie