Jak vám dnes můžeme pomoci?

Video: How do you reset the ATS48 soft starter back to factory default?

Issue:
ATS48 factory reset

Product Line:
Altistart 48

Resolution:
Programming menu:
RDY arrow down to
DRC menu
FCS setting set this to Yes, and hold it for 3 seconds.
Complete now your soft starter is reset back to the factory settings.