Jak vám dnes můžeme pomoci?
How to change an ATV630 programming, so that it is a heavy duty rated drive instead of normal duty?
Issue:
Programming ATV630 for Heavy Duty.
Product Line:
Altivar 630
Environment:
All
Cause:
Rating
Resolution:
Change from normal duty to heavy duty under motor control menu for dual rating.
Change Motor control type to standard from quad.
Note: The rating of the drive does drop by 1 frame size if the drive is heavy duty rated instead of normal duty.
Programming ATV630 for Heavy Duty.
Product Line:
Altivar 630
Environment:
All
Cause:
Rating
Resolution:
Change from normal duty to heavy duty under motor control menu for dual rating.
Change Motor control type to standard from quad.
Note: The rating of the drive does drop by 1 frame size if the drive is heavy duty rated instead of normal duty.