Is it possible to dynamically change the Sender Name in an Email during Vijeo Designer Runtime?
Issue:
Is it possible to dynamically change the Sender Name in an Email during Vijeo Designer Runtime?
Product Line:
Vijeo Designer (all versions)
Resolution:
No, the Sender name in the E-mail configuration for an Magelis HMI is static. We are unable to change the value of the field for Sender Name during runtime. As a workaround, you could embed a variable into the Subject field or Body of the email containing the value of the Sender's Name.
If this FAQ did not solve your issue, you can chat with us at chat with us or e-mail us at customer.services@se.com to create a case with our Technical Support Team.