Jak vám dnes můžeme pomoci?

Video: How to configure the HMIBSC Edge Box as a 4G router

Question
How to configure the HMIBSC Edge Box as a 4G router


Description
1- Create the IP_Forwarding script
~# vi /etc/init.d/IP_Forwarding.sh
#!/bin/sh
loadkeys fr # To set the keyboard - optional if you prefer use a qwerty keyboard
echo 1 > /proc/sys/net/ipv4/ip_forward
iptables -t nat -A POSTROUTING -o usb0 -j MASQUERADE
Save file with :wq
2- Create a link in the correct run level
~# ln -s /etc/init.d/IP_Forwarding.sh /etc/rc3.d/S98IP_Forwarding #The RC number depend of your run level
3- Add the executable right for the script
~# chmod 755 /etc/init.d/IP_Forwarding.sh
~# ls -l /etc/init.d/IP_Forwarding.sh # rwxr-xr-x rights
4- ~# reboot


Keywords
Schneider Electric, HMIBSC, BSC, Edge Box, Configuration, 4G, router

Case author:
Lilian Cabos

Product Familly
IIOT Edge Box

Schneider Electric Česká republika

Zjistěte více
Řada:
Zjistěte více
Řada:
  • Dokumentace k produktům
  • Software ke stažení
  • Nástroj pro výběr produktů
  • Hledání náhrady za produkty
  • Centrum nápovědy a kontakty
  • Najít naše pobočky
  • Získejte nabídku
  • Kde koupit
  • Komunita Schneider Electric
  • Kariéra
  • Profil společnosti
  • Nahlásit nevhodné chování
  • Přístupnost
  • Newsroom
  • Investoři
  • EcoStruxure
  • Vyhledávání pracovních míst
  • Blog
  • Zásady ochrany osobních údajů
  • Oznámení o souborech cookie
  • Podmínky použití
  • Změnit nastavení souborů cookie