Naše značky

Vítejte na internetových stránkách společnosti Schneider Electric

Vítejte na našich internetových stránkách.
		
Jak vám dnes můžeme pomoci?
EcoStruxure Operator Terminal Expert - How do I set up a custom image or logo during bootup on my HMI?

Article available in these languages: Španělština

Issue
During the bootup sequence of my HMI that is configured with EcoStruxure Operator Terminal Expert, I'd like to see my company logo image. How do I configure it?

Product Line
EcoStruxure Operator Terminal Expert v3.1 or higher

Environment
HMI Programming Software in Windows

Resolution
The HMI boot screen image can be changed to show a .PNG file format image.
In EcoStruxure Operator Terminal Expert Configuration Software, the Boot Screen Image may be customized by following these steps:
1) Under Project Explorer, expand "System Architecture"
2) Double-click on "Target01"- On the far right side of your screen, you will see the Properties screen appear
3) Click on the Function tab
4) Click on the Options Tab
5) Next to "Boot Screen Image", click the [...] button
6) From your Windows File System, choose an image file of .PNG format.
Boot Screen Image property

Schneider Electric Česká republika

Zjistěte více
Řada:
Zjistěte více
Řada:
  • Dokumentace k produktům
  • Software ke stažení
  • Nástroj pro výběr produktů
  • Hledání náhrady za produkty
  • Centrum nápovědy a kontakty
  • Najít naše pobočky
  • Získejte nabídku
  • Kde koupit
  • Komunita Schneider Electric
  • Kariéra
  • Profil společnosti
  • Nahlásit nevhodné chování
  • Přístupnost
  • Newsroom
  • Investoři
  • EcoStruxure
  • Vyhledávání pracovních míst
  • Blog
  • Zásady ochrany osobních údajů
  • Oznámení o souborech cookie
  • Podmínky použití
  • Změnit nastavení souborů cookie