Jak vám dnes můžeme pomoci?

Obtain SQL Login Password Related Information

Issue
How to list SQL login password related information from the SQL database.

Product Line

ION Enterprise 6.0. x

Struxureware Power Monitoring 7.0.x
Power Monitoring Expert 7.2.2
Power Monitoring Expert 8.2
Power Monitoring Expert 9.0

Environment
SQL Server 2005, SQL Server 2008 R 2, SQL Server 2012, SQL Server 2014, SQL Server 2016, SQL Server 2017

Cause
In order to troubleshoot and validate SQL login issues, it may be necessary to ensure that the account and credentials being
used to access the database are in fact valid and have not been disabled or locked out.

Resolution
*Warning: Irreparable database damage can occur. This procedure should only be performed by users familiar with SQL Server Management Studio.
Databases should be backed up prior to performing this procedure.*

With this SQL statement you can query this information for all SQL logins and calculate the date for password.
This will also return login information such as the last time the password has been change, how many days it take till the password expires,
how often a bad password was entered or if the login is already locked.

To obtain this list, log into SQL Server Management Studio and run the attached SQL script (LoginPassword.sql).
Alternatively, execute the query(s) below:

SELECT SL.name AS LoginName 
      ,LOGINPROPERTY (SL.name, 'PasswordLastSetTime') AS PasswordLastSetTime 
      ,LOGINPROPERTY (SL.name, 'DaysUntilExpiration') AS DaysUntilExpiration 
      ,DATEADD(dd, CONVERT(int, LOGINPROPERTY (SL.name, 'DaysUntilExpiration')) 
                 , CONVERT(datetime, LOGINPROPERTY (SL.name, 'PasswordLastSetTime'))) AS PasswordExpiration 
      ,SL.is_policy_checked AS IsPolicyChecked 
      ,LOGINPROPERTY (SL.name, 'IsExpired') AS IsExpired 
      ,LOGINPROPERTY (SL.name, 'IsMustChange') AS IsMustChange 
      ,LOGINPROPERTY (SL.name, 'IsLocked') AS IsLocked 
      ,LOGINPROPERTY (SL.name, 'LockoutTime') AS LockoutTime 
      ,LOGINPROPERTY (SL.name, 'BadPasswordCount') AS BadPasswordCount 
      ,LOGINPROPERTY (SL.name, 'BadPasswordTime') AS BadPasswordTime 
      ,LOGINPROPERTY (SL.name, 'HistoryLength') AS HistoryLength 
FROM sys.sql_logins AS SL 
WHERE is_expiration_checked = 1 
ORDER BY LOGINPROPERTY (SL.name, 'PasswordLastSetTime') DESC

Schneider Electric Česká republika

Přílohy

Zjistěte více

Potřebujete pomoc?

Nástroj pro výběr produktů

Rychle a snadno vyhledávejte správné produkty a příslušenství pro vaše aplikace.

Získejte nabídku

Poptejte se nás online a náš lokální specialista se s vámi spojí!

Kde nakoupit?

Jednoduše najděte nejbližšího distributora výrobků Schneider Electric ve vašem okolí.

Centrum nápovědy

Zdroje podpory pro všechny své potřeby najdete na jednom místě.