Galaxy RPP “Fingersafe IP2X” NQ Panelboards

Article available in these languages:

  • Španělština

Issue:
The new Galaxy RPP has multiple panelboard options.  One of them is the IP2X Fingersafe panelboard which greatly restricts exposure to live parts.

These panelboards use the standard Square D QOB breakers but require some adapters to make them fit and increase safety.

Product line:
GRPPIP2X84, GRPPIP2X89

Environment:
All models, all serial numbers

Cause:
Electrocution is one of the top causes of construction injury.  The NQ panelboard reduces this risk by limiting exposure to live components.

Resolution:
To install standard Sq D QOB breakers into the Galaxy RPP with the NQ Panelboard, you will need an accessory jaw kit, and Fingersafe Barriers.

Parts:

Catalog NumberQuantity per packageDescription
QOFSBF1212NQ IP2X Bus Finger Filler *3
QOFSLALB1212NQ IP2X QO(B) Lug Cover Low Amp
QOFSHALB1212NQ IP2X QO(B) Lug Cover High Amp
QO1PJ1515QOB Jaw Kit4
QOBRT1QOB Breaker Removal Kit *4
*3 Used only with Standard IP2X design
*4 Used only with Enhanced IP2X design

Note:

IP2X finger-safe protection uses bus finger filler covers installed in empty breaker spaces, whereas Enhanced IP2X protection covers the bus itself, eliminating the need for breaker filler covers in unused spaces.


References:
https://www.se.com/us/en/product/GRPPIP2X84/galaxy-rpp-with-fingersafe-ip2x-panelboard-white/

https://download.schneider-electric.com/files?p_File_Name=998-20824083_GMA-US_Galaxy+RPP+brochure_HR_WEB.pdf&p_Doc_Ref=GalaxyRPP_Brochure_EN&p_enDocType=Catalog

https://download.schneider-electric.com/files?p_enDocType=Brochure&p_File_Name=1640BR1701_NQ_FingerSafe1-2019.pdf&p_Doc_Ref=1640BR1701

Schneider Electric Česká republika

Přílohy
998-20824083_GMA-US_Galaxy RPP brochure_HR_WEB.pdf [3.82 MB]
1640BR1701_NQ_FingerSafe1-2019.pdf [1.09 MB]
Zjistěte více
Produkt:
Řada:
Zjistěte více
Produkt:
Řada:
  • Dokumentace k produktům
  • Software ke stažení
  • Nástroj pro výběr produktů
  • Hledání náhrady za produkty
  • Centrum nápovědy a kontakty
  • Najít naše pobočky
  • Získejte nabídku
  • Kde koupit
  • Komunita Schneider Electric
  • Kariéra
  • Profil společnosti
  • Nahlásit nevhodné chování
  • Přístupnost
  • Newsroom
  • Investoři
  • EcoStruxure
  • Vyhledávání pracovních míst
  • Blog
  • Všeobecné obchodní podmínky
  • Zásady ochrany osobních údajů
  • Oznámení o souborech cookie
  • Podmínky použití
  • Změnit nastavení souborů cookie