Jaká je doporučená náhrada XPSAK za univerzální XPSU?

XPSAK je nahrazen XPSUAK - 24DC

Popis
ReferenceDoporučená náhrada
XPSAK311144XPSUAK12AP
XPSAK311144PXPSUAK12AP

Schéma pro zapojení svorek na XPSU:
Popis
XPSAK je nahrazen XPSUAK - 48...230V
Popis
ReferenceDoporučená náhrada
XPSAK331144PXPSUAK32AP
XPSAK351144XPSUAK32AP
XPSAK351144PXPSUAK32AP
XPSAK361144XPSUAK32AP
XPSAK361144PXPSUAK32AP
XPSAK371144XPSUAK32AP
XPSAK371144PXPSUAK32AP

Schéma pro zapojení svorek na XPSU:
Popis
Zapojení jednokanálového Emergency Stop pro XPSAK & XPSUAK
Popis
Zapojení dvoukanálového Emergency Stop pro XPSAK & XPSUAK

Popis
PopisZapojení dvoukanálových Emergency Stop v sérii pro XPSAK & XPSUAK
Popis
Popis
Zapojení Safety Switch pro XPSAK & XPSUAK
Popis
Popis

Popis

Zapojení Safety Mat pro XPSAK & XPSUAK
Popis
Zapojení Sensors with PNP výstupy pro XPSAK & XPSUAK
Popis
Zapojení Sensors with PNP and NPN výstupy pro XPSAK & XPSUAK
Popis
Zapojení Safety Light Curtains or RFID Sensors pro XPSAK & XPSUAK
Popis

⚠ CAUTION ⚠

The information provided in this documentation contains general descriptions and/or technical characteristics of the performance of the products contained herein. This documentation is not intended as a substitute for and is not to be used for determining suitability or reliability of these products for specific user applications. It is the duty of any such user or integrator to perform the appropriate and complete risk analysis, evaluation and testing of the products with respect to the relevant specific application or use thereof. Neither Schneider Electric nor any of its affiliates or subsidiaries shall be responsible or liable for misuse of the information contained herein. If you have any suggestions for improvements or amendments or have found errors in this publication, please notify us.

You agree not to reproduce, other than for your own personal, noncommercial use, all or part of this document on any medium whatsoever without permission of Schneider Electric, given in writing. You also agree not to establish any hypertext links to this document or its content. Schneider Electric does not grant any right or license for the personal and noncommercial use of the document or its content, except for a non-exclusive license to consult it on an "as is" basis, at your own risk. All other rights are reserved.

All pertinent state, regional, and local safety regulations must be observed when installing and using this product. For reasons of safety and to help ensure compliance with documented system data, only the manufacturer should perform repairs to components.

When devices are used for applications with technical safety requirements, the relevant instructions must be followed.

Failure to use Schneider Electric software or approved software with our hardware products may result in injury, harm, or improper operating results.

Failure to observe this information can result in injury or equipment damage.

© 2021 Schneider Electric. All rights reserved.

Schneider Electric Česká republika

Přílohy
XPSUAK_AK.pdf [1.01 MB]
Zjistěte více
Produkt:
Zjistěte více
Produkt:
  • Dokumentace k produktům
  • Software ke stažení
  • Nástroj pro výběr produktů
  • Hledání náhrady za produkty
  • Centrum nápovědy a kontakty
  • Najít naše pobočky
  • Získejte nabídku
  • Kde koupit
  • Komunita Schneider Electric
  • Kariéra
  • Profil společnosti
  • Nahlásit nevhodné chování
  • Přístupnost
  • Newsroom
  • Investoři
  • EcoStruxure
  • Vyhledávání pracovních míst
  • Blog
  • Všeobecné obchodní podmínky
  • Zásady ochrany osobních údajů
  • Oznámení o souborech cookie
  • Podmínky použití
  • Změnit nastavení souborů cookie