Video: Setting up the Edge IO with Machine Expert V2.3 and a M262 using Ethernet/IP protocol
Issue:
Setting up the Edge IO with Machine Expert V2.3 and a M262 using Ethernet/IP protocol.
Product Line:
Edge IO, Machine Expert, M262 PLC
Resolution:
Please see video for configuration
Hardware:
| TM262M35MESS8T | M262 Controller |
| NTSNEC1200 | Edge I/O - Network Interface Module Ethernet/IP, Modbus/TCP |
| NTSPFB1002H | Edge I/O Power Supply Module |
| NTSDDI1602X | Edge I/O – Discrete Input Module, 16 In |
| NTSDDO0802 | Edge I/O – Discrete Output Module 8 Out |
| NTSAMI0400 | Edge I/O – Analog Input 4 In |
| NTXAMO0400 | Edge I/O – Analog Output 4 Out |
- Creating a BOM using the Configuration tool
- Connecting to the Web Server of the Edge I/O
- Mapping the Edge I/O modules with Machine Expert V2.3
- Mapping through the EDS file.
- EcoStruxure Automation Device Maintenance Tool (EADM)
Default User: SecurityAdmin
Default Password: AAAAAAAA
Default IP address: 10.10.X.X, where the last two octets are derived from the MAC address (converted from hexadecimal to decimal).
00:00:54:C8:05:83 à 10.10.5.131
Rotary Switch Settings
| TENS (x) | ONES (y) | Mode | Description |
| 0–15 | 0–9 | DHCP | Enables DHCP for automatic IP assignment. Allows device naming for DHCP/FDR server. |
| Any | BootP | BootP | Requests IP parameters using the device MAC address from a BootP server. |
| Any | Stored | Stored IP | Uses saved or default IP address. |
| Any | Clear | Clear / Reset | Clears IP and stored configuration. |