Nuestras marcas

Web de Schneider Electric España

Bienvenido a nuestra web
		
¿Cómo podemos ayudarle hoy?
Video: When to use the Internet Explorer Browser object in Vijeo Designer
Issue:
Looking for a way to view a website within the Vijeo Designer Runtime

Product Line:
Harmony / Magelis iPC or HMI targets running Windows Operating Systems

Resolution:
The Internet Explorer browser object in Vijeo Designer is only to be used with iPC or HMI targets running Windows Operating Systems. When using this object in a Windows environment, you will be able to open web pages as you would on your regular PC within the Vijeo Designer Runtime window.

When using HMIs such HMISTU, HMISTO, XBTGT, XBTGK, HMIGTO, HMIGTU, use the Multi-platform Browser Object instead. This object will allow you to open pre-downloaded files such as HTML that you include at Data Files node in Vijeo Designer.

Schneider Electric España

Explorar más
Rango:
Explorar más
Rango:
  • Documentación de productos
  • Descargas de software
  • Selector de productos
  • Reemplazo de productos
  • Centro de ayuda y contacto
  • Encuentra nuestras oficinas
  • Pedir presupuesto
  • Dónde comprar
  • Closure of shop.se.com/es/es/ and shop.se.com/pro/es/es/
  • Schneider Electric Community
  • Carreras
  • Perfil corporativo
  • Denunciar una mala conducta
  • Accesibilidad
  • Sala de prensa
  • Inversores
  • EcoStruxure
  • Búsqueda de empleo
  • Blog
  • Política de privacidad
  • Aviso de Cookies
  • Condiciones de uso
  • Cambiar tu configuración de cookies