Issue
How to obtain all the details of all SQL Jobs created on a SQL server instance.

Product Line

Power Monitoring Expert 7.2.2
Power Monitoring Expert 8.2
Power Monitoring Expert 9.0
Power Monitoring Expert 2020
Power Monitoring Expert 2021
Power Monitoring Expert 2022
Power Monitoring Expert 2023
Power Monitoring Expert 2024



Environment
Microsoft SQL Server

SQL Server Management Studios

Cause
For daily monitoring purposes or for troubleshooting SQL job issues, obtaining information about the SQL jobs via a single query can be a very useful and time-saving alternative method.

Resolution
*Warning: Irreparable database damage can occur. This procedure should only be performed by users familiar with SQL Server Management Studio. Databases should be backed up prior to performing this procedure.*

This query will provide the SQL Server job details for all jobs present.  It will provide the job name, job status, Last run date of the job & job execution status (failed or successful)
It may also be modified to add or change the fields reported as per the requirement.

To obtain these job details, log into SQL Server Management Studio and run the attached SQL script (SQL_Job_Details.sql).
Alternatively, execute the query(s) below:

Use msdb 
go 
select distinct j.Name as "Job Name", --j.job_id, 
case j.enabled  
when 1 then 'Enable'  
when 0 then 'Disable'  
end as "Job Status", jh.run_date as [Last_Run_Date(YY-MM-DD)] ,  
case jh.run_status  
when 0 then 'Failed'  
when 1 then 'Successful'  
when 2 then 'Retry' 
when 3 then 'Cancelled'  
when 4 then 'In Progress'  
end as Job_Execution_Status 
from sysJobHistory jh, sysJobs j 
where j.job_id = jh.job_id and jh.run_date =   
(select max(hi.run_date) from sysJobHistory hi where jh.job_id = hi.job_id )-- to get latest date


Schneider Electric España

Documentos adjuntos
SQL_Job_Details.sql [566 Bytes]
Explorar más
Producto:
Explorar más
Producto:
  • Documentación de productos
  • Descargas de software
  • Selector de productos
  • Reemplazo de productos
  • Centro de ayuda y contacto
  • Encuentra nuestras oficinas
  • Pedir presupuesto
  • Dónde comprar
  • Closure of shop.se.com/es/es/ and shop.se.com/pro/es/es/
  • Schneider Electric Community
  • Carreras
  • Perfil corporativo
  • Denunciar una mala conducta
  • Accesibilidad
  • Sala de prensa
  • Inversores
  • EcoStruxure
  • Búsqueda de empleo
  • Blog
  • Condiciones generales de contratación
  • Política de privacidad
  • Aviso de Cookies
  • Condiciones de uso
  • Cambiar tu configuración de cookies
  • Centro de Preferencias