Miniature circuit-breaker, Acti9 iC40N, 3P+N, 20 A, C curve, 6000 A (IEC 60898-1), 10 kA (IEC 60947-2)

A9P54720

Save space in your switchboard
Combine short-circuit and overload currents protection
Visitrip system for fast detection of faulty outgoers for shorter repair times
VisiSafe system for offering enhanced security when it comes to circuit protection
Option to add auxiliaries, remote monitoring and residual current device (Vigi)
Environmental Data
Total lifecycle Carbon footprint
4
Use Better
Packaging made with recycled cardboard
information_stroke
Recycled cardboard content is minimum 70% (50% in US). Some orders may include non-recycled cardboard until stock runs out.
Yes
Use Again
Take-back
information_stroke
Whether the product has been included in a global take-back program. Some products are eligible in some geographies, please verify if it's available in your country.
No
Description
arrow2_down
This Acti9 iC40N product is a low voltage miniature circuit breaker (MCB). It is a 3P+N circuit breaker with 3 protected poles and 20A In rated current and C tripping curve. The rated short circuit breaking capacity goes up to 10kA at 400VAC conforming to EN/IEC 60947-2 standard and 6000A at 400VAC conforming to EN/IEC 60898-1 standard. This product complies with both industrial standard EN/IEC 60898-1 and residential standard EN/IEC 60947-2. This miniature circuit breaker combines functions of circuit protection against short circuit and overload current, control and isolation. The installation and cabling are simplified with clip on function as well as ease of maintenance. It has an electrical endurance going up to 20000 cycles and a mechanical endurance going up to 20000 cycles. The Ue operational voltage is 400VAC. The Ui rated insulation voltage is 440VAC. The Uimp rated impulse withstand voltage is 4kV. The operating frequency is 50Hz or 60Hz. It can be mounted on DIN rail for modular installation. Its width is 6 pitches of 9mm. Pollution degree is 3. The product colour is white (RAL9003). The dimensions are (W) 54mm x (H) 85mm x (D) 74mm. The weight is 345g. According to IEC 60529 standard, the degree of protection is IP20 and IP40 in enclosure. The operating temperature is -25°C to 70°C. The storage temperature is -40°C to 85°C.
Specifications
arrow2_down
Main
RangeActi9
Product nameActi9 iC40
Product or component typeMiniature circuit-breaker
Device short nameiC40N
Device applicationDistribution
Poles description3P + N
Number of protected poles3
Neutral positionLeft
[In] rated current20 A
Network typeAC
Trip unit technologyThermal-magnetic
Curve codeC
Breaking capacity10 kA Icu at 400 V AC 50/60 Hz conforming to EN/IEC 60947-2
6000 A Icn at 400 V AC 50/60 Hz conforming to EN/IEC 60898-1
Suitability for isolationYes conforming to EN/IEC 60947-2
Quality labelsAENOR
IMQ
OVE
Complementary
Network frequency50/60 Hz
[Ue] rated operational voltage400 V AC 50/60 Hz
Magnetic tripping limit5...10 x In conforming to EN/IEC 60898-1
8 x In +/- 20 % conforming to EN/IEC 60947-2
[Ics] rated service breaking capacity6000 A 100 % x Icn at 400 V AC 50/60 Hz conforming to EN/IEC 60898-1
7.5 kA 75 % x Icn at 400 V AC 50/60 Hz conforming to EN/IEC 60947-2
Limitation class3 conforming to EN/IEC 60898-1
[Ui] rated insulation voltage440 V AC 50/60 Hz conforming to EN/IEC 60947-2
[Uimp] rated impulse withstand voltage4 kV conforming to EN/IEC 60947-2
Contact position indicatorYes
Control typeToggle
Local signallingON/OFF indication
Trip indicator
Mounting modeClip-on
Mounting supportDIN rail
9 mm pitches6
Height85 mm
Width54 mm
Depth74 mm
Net weight345 g
ColourWhite
Mechanical durability20000 cycles
Electrical durability20000 cycles
Locking options descriptionPadlocking device
Connections - terminalsTunnel type terminals top or bottom 1…10 mm² flexible
Tunnel type terminals top or bottom 1…16 mm² rigid
Wire stripping length14 mm for top or bottom connection
Tightening torque2 N.m top or bottom
Earth-leakage protectionSeparate block
Environment
StandardsEN/IEC 60898-1
EN/IEC 60947-2
Product certificationsCE
BV
RINA
DNV
IP degree of protectionIP20 conforming to IEC 60529
IP40 (modular enclosure) conforming to IEC 60529
Pollution degree3 conforming to EN/IEC 60947-2
Relative humidity95 % at 55 °C
Operating altitude2000 m
Ambient air temperature for operation-25…70 °C
Ambient air temperature for storage-40…85 °C
Packing Units
Unit Type of Package 1PCE
Number of Units in Package 11
Package 1 Height5.400 cm
Package 1 Width7.400 cm
Package 1 Length9.400 cm
Package 1 Weight332.000 g
Unit Type of Package 2BB1
Number of Units in Package 24
Package 2 Height8.500 cm
Package 2 Width9.500 cm
Package 2 Length21.500 cm
Package 2 Weight1.384 kg
Unit Type of Package 3S03
Number of Units in Package 344
Package 3 Height30.000 cm
Package 3 Width30.000 cm
Package 3 Length40.000 cm
Package 3 Weight15.524 kg
arrow2_down
Schneider Electric aims to achieve Net Zero status by 2050 through supply chain partnerships, lower impact materials, and circularity via our ongoing “Use Better, Use Longer, Use Again” campaign to extend product lifetimes and recyclability.
Environmental footprint
Use Better
Materials and Substances
Use Again
Repack and remanufacture
Documents
arrow2_down
Software and Firmware
arrow2_down
arrow2_down

Need more information? Check our technical FAQs!

Easily find answers to the most frequently asked questions.

  • Products Documentation
  • Software Downloads
  • Product Selector
  • Product Substitution and Replacement
  • Contact Support
  • Find our Offices
  • Need help? Start here
  • Where to buy
  • Careers
  • Company Profile
  • Newsroom
  • Investors
  • EcoStruxure
  • Job Search
  • Blog
  • Data Privacy
  • Cookies Policy
  • Terms of use
  • Change your cookie settings