TeSys LRF - electronic thermal overload relay - 200...330 A - class 10

LR9F7375

Recommended replacement(s)

LR9F7375 is replaced by:
Environmental Data
Total lifecycle Carbon footprint
355
Use Better
Packaging made with recycled cardboard
information_stroke
Recycled cardboard content is minimum 70% (50% in US). Some orders may include non-recycled cardboard until stock runs out.
No
Use Again
Take-back
information_stroke
Whether the product has been included in a global take-back program. Some products are eligible in some geographies, please verify if it's available in your country.
No
Description
arrow2_down
TeSys LR9F electronic overload relay, thermal setting range 200-330A, class 10, for protection of motors 132-160kW@400V. to be mounted directly below a TeSys F 3-pole contactor LC1 F225, F265, F330, F400, F500, use of a support mounting plate LA7F902 is mandatory (to be ordered separately). Motor protection includes thermal overload of 1-phase and 3-phase motors, phase failure, phase unbalance, prolonged starting times, stalled rotor conditions. On the front of the relay, it provides a thermal adjustement dial, buttons for test, stop & reset, a trip indicator, trip auxiliary contacts 1NO+1NC. Multi standards certified (IEC, UL, CSA, CCC, Marine), Green Premium compliant (RoHs/Reach).
Specifications
arrow2_down
Main
RangeTeSys
Product nameTeSys LRF
Device short nameLR9F
Product or component typeElectronic thermal overload relay
Relay applicationMotor protection
Product compatibilityLC1F225...LC1F500
Network typeAC
Thermal overload classClass 10 conforming to IEC 60947-4
Thermal protection adjustment range200…330 A
Complementary
Network frequency50/60 Hz
Mounting supportDirect on contactor
Plate
Tripping threshold1.12 +/- 0.06 In tripping conforming to IEC 60947-4-1
Surge withstand4 kV conforming to IEC 61000-4-5
Contacts type and composition1 NO + 1 NC
[Ith] conventional free air thermal current5 A for control circuit
[Ue] rated operational voltage1000 V AC 50/60 Hz for power circuit conforming to VDE 0110 group C
[Ui] rated insulation voltagePower circuit: 1000 V AC conforming to IEC 60947-4
[Uimp] rated impulse withstand voltage8 kV conforming to IEC 60947-1
Phase failure sensitivityTripping in 4 s +/- 20 % conforming to IEC 60947-4-1
ResetManual reset on front relay
Control typeDial white full-load current adjustment
Test button red
Push-button red reset
Push-button stop
Local signallingTrip indicator
Temperature compensation-20…70 °C
Current consumption<= 5 mA no-load
switching capacity for alarm0...150 mA
Maximum voltage drop<2.5 V closed state
Connections - terminalsControl circuit: screw clamp terminals 1 cable 0.75…2.5 mm² - cable stiffness: flexible - with cable end
Control circuit: screw clamp terminals 1 cable 0.75…2.5 mm² - cable stiffness: solid
Control circuit: screw clamp terminals 1 cable 0.75…4 mm² - cable stiffness: flexible - without cable end
Control circuit: screw clamp terminals 2 cable 1…1.5 mm² - cable stiffness: flexible - with cable end
Control circuit: screw clamp terminals 2 cable 1…2.5 mm² - cable stiffness: flexible - without cable end
Control circuit: screw clamp terminals 2 cable 1 mm² - cable stiffness: solid
Power circuit: lugs-ring terminals M10
Tightening torqueControl circuit: 1.2 N.m on screw clamp terminals
Power circuit: 35 N.m on screw clamp terminals
Height136.8 mm
Width150 mm
Depth127.6 mm
Net weight2.32 kg
Environment
StandardsVDE 0660
IEC 60947-4-1
EN 60947-4-1
IEC 60255-17
IEC 60255-8
Product certificationsUL
CSA
UKCA
Protective treatmentTH
IP degree of protectionIP20 conforming to IEC 60529
IP20 conforming to VDE 0106
Ambient air temperature for operation-20…55 °C conforming to IEC 60255-8
Ambient air temperature for storage-40…85 °C
Operating altitude<= 2000 m without derating
Fire resistance850 °C conforming to IEC 60695-2-1
Mechanical robustnessShocks: 13 Gn for 11 ms conforming to IEC 60068-2-7
Vibrations 5...300 Hz: 2 GN conforming to IEC 60068-2-6
Dielectric strength6 kV 50 Hz conforming to IEC 255-5
Electromagnetic compatibilityResistance to electrostatic discharge: 6 kV in indirect mode conforming to IEC 61000-4-2
Resistance to electrostatic discharge: 8 kV in air conforming to IEC 61000-4-2
Radiated radio-frequency electromagnetic field immunity test: 10 V/m conforming to IEC 61000-4-3
Fast transients immunity test: 2 kV conforming to IEC 61000-4-4
Packing Units
Unit Type of Package 1PCE
Number of Units in Package 11
Package 1 Height18.000 cm
Package 1 Width20.000 cm
Package 1 Length19.500 cm
Package 1 Weight1.882 kg
Unit Type of Package 2P06
Number of Units in Package 236
Package 2 Height75.000 cm
Package 2 Width60.000 cm
Package 2 Length80.000 cm
Package 2 Weight79.896 kg
Contractual warranty
Warranty12 months
arrow2_down
Schneider Electric aims to achieve Net Zero status by 2050 through supply chain partnerships, lower impact materials, and circularity via our ongoing “Use Better, Use Longer, Use Again” campaign to extend product lifetimes and recyclability.
Environmental footprint
Use Better
Materials and Substances
Use Again
Repack and remanufacture
Documents
arrow2_down
Software and Firmware
arrow2_down

Need more information? Check our technical FAQs!

Easily find answers to the most frequently asked questions.

  • Products Documentation
  • Software Downloads
  • Product Selector
  • Product Substitution and Replacement
  • Contact Support
  • Find our Offices
  • Need help? Start here
  • Where to buy
  • Careers
  • Company Profile
  • Newsroom
  • Investors
  • EcoStruxure
  • Job Search
  • Blog
  • Data Privacy
  • Cookies Policy
  • Terms of use
  • Change your cookie settings