Thermal protection adjustment range:
Environmental Data
Total lifecycle Carbon footprint
666
Use Better
Packaging made with recycled cardboard
Yes
Use Again
Take-back
No
TeSys LR9G 500A thermal overload relay is compatible with TeSys Giga high power contactor, push-in control connection. It provides phase imbalance, phase failure, in-built ground-fault and single-phase loads protections. It is available for manual and auto reset options and LED indicator for Motor ON and pre-trip alarm. Tripping classes is selectable from class 5E to class 30E to suit different application needs from fast tripping, general purpose and high inertia loads. It is suitable for independent mounting or direct mounting with LC1G contactors. It provides IP2x protection in Front face with shrouds conforming to IEC 60529 and VDE 0106. It can cover -25°C to 60°C operation ambient air temperature without derating up to 3000m altitude. Multi standards certified (CE,CB,CCC,cULus,EAC,KC,RCM,Marine) and Green Premium compliant (RoHs/Reach). Unique QR code provides quick access to complete product data.
Range | TeSys |
---|---|
Product name | TeSys LRG |
Product or component type | Electronic thermal overload relay |
Device short name | LR9G |
Relay application | Motor protection |
Network type | AC |
Thermal overload class | Class 5E...30E conforming to IEC 60947-4-1 |
Thermal protection adjustment range | 125…500 A |
Network frequency | 30...60 Hz 100 Hz |
---|---|
Overvoltage category | III |
Tripping threshold | 1.125 +/- 0.07 In conforming to IEC 60947-4-1 |
Protection type | Ground fault protection - tripping time adjustment: 0…1 s - for alarm circuit conforming to IEC 60947-4-1 Ground fault protection - tripping time adjustment: 0…1 s - for alarm circuit conforming to UL 60947-4-1 Phase loss - tripping time adjustment: 0…4 s - for alarm circuit Phase imbalance - tripping time adjustment: 0…5 s - for alarm circuit conforming to IEC 60947-4-1 Phase imbalance - tripping time adjustment: 0…5 s - for alarm circuit conforming to UL 60947-4-1 |
Local signalling | LED Trip indicator |
Contacts type and composition | 1 NO + 1 NC |
[Ith] conventional free air thermal current | 5 A |
[Uc] control circuit voltage | 24...500 V AC 50/60 Hz 24...250 V DC |
[Ue] rated operational voltage | 1000 V AC 50/60 Hz |
[Uimp] rated impulse withstand voltage | 8 kV |
Reset | Automatic reset Manual |
Mechanical durability | 7000 cycles |
Surge withstand | 4 kV |
Electromagnetic compatibility | EMC immunity conforming to IEC 60947-4-1 Emission tests criteria A conforming to IEC 60947-4-1 Immunity to radiated radio-electrical interference - test level: 20 V/m conforming to EN/IEC 61000-4-3 Voltage dips and interruptions immunity test conforming to SEMI F47 |
Connections - terminals | Power circuit: bar - busbar cross section: 32 x 10 mm Power circuit: lugs-ring terminals 1 240 mm² Control circuit: push-in 1 0.2…2.5 mm² - cable stiffness: solid stranded without cable end Control circuit: push-in 1 0.25…2.5 mm² - cable stiffness: flexible with cable end Control circuit: push-in 2 0.5…1.0 mm² with cable end |
Tightening torque | 35 N.m |
Mounting support | Direct on contactor Plate |
Standards | EN/IEC 60947-4-1 EN/IEC 60947-5-1 UL 60947-4-1 CSA C22.2 No 60947-4-1 JIS C8201-4-1 JIS C8201-5-1 IEC 60335-1:Clause 30.2 IEC 60335-2-40:Annex JJ UL 60335-2-40:Annex JJ UL 60335-1 |
Product certifications | CB Scheme CCC cULus UKCA ATEX EU-RO-MR by DNV-GL EAC |
IP degree of protection | IP2X front face with shrouds conforming to IEC 60529 IP2X front face with shrouds conforming to VDE 0106 |
---|---|
Protective treatment | TH |
Ambient air temperature for operation | -25…60 °C |
Ambient air temperature for storage | -60…80 °C |
Permissible ambient air temperature around the device | -40…60 °C at Uc |
Adjustment of dial setting | -25…60 °C |
Mechanical robustness | Vibrations 5…300 Hz 6 gn contactor open Shocks 15 gn 11 ms contactor closed |
Height | 114 mm |
Width | 140 mm |
Depth | 140 mm |
Net weight | 1.3 kg |
Colour | Dark grey |
Unit Type of Package 1 | PCE |
---|---|
Number of Units in Package 1 | 1 |
Package 1 Height | 18.500 cm |
Package 1 Width | 19.000 cm |
Package 1 Length | 24.000 cm |
Package 1 Weight | 2.104 kg |
Unit Type of Package 2 | S03 |
Number of Units in Package 2 | 2 |
Package 2 Height | 30.000 cm |
Package 2 Width | 30.000 cm |
Package 2 Length | 40.000 cm |
Package 2 Weight | 4.733 kg |
Unit Type of Package 3 | P06 |
Number of Units in Package 3 | 16 |
Package 3 Height | 75.000 cm |
Package 3 Width | 60.000 cm |
Package 3 Length | 80.000 cm |
Package 3 Weight | 45.864 kg |
Schneider Electric aims to achieve Net Zero status by 2050 through supply chain partnerships, lower impact materials, and circularity via our ongoing “Use Better, Use Longer, Use Again” campaign to extend product lifetimes and recyclability.
Total lifecycle Carbon footprint
666
Environmental Disclosure
Use Better
Packaging made with recycled cardboard
Yes
Packaging without single use plastic
No
Compliant with Exemptions
SCIP Number
958748fb-37b2-4e37-985e-0763521c22ab
REACh Regulation
Halogen-free status
Halogen free plastic parts product
PVC free
Yes
Use Again
End of life manual availability
Take-back
No
WEEE Label

The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins