ION8650 meter 128MB, 9S/29S/36S, 277VAC 50Hz, Ethernet 3I+4O, password

M8650A0C0E5E1B1A

Recommended replacement(s)

M8650A0C0E5E1B1A is replaced by the following product range:
Environmental Data
Total lifecycle Carbon footprint
391
Use Better
Packaging made with recycled cardboard
information_stroke
Recycled cardboard content is minimum 70% (50% in US). Some orders may include non-recycled cardboard until stock runs out.
No
Use Again
Take-back
information_stroke
Whether the product has been included in a global take-back program. Some products are eligible in some geographies, please verify if it's available in your country.
No
Description
arrow2_down
The PowerLogic ION8650 series meters are ideal for energy, power quality metering and independent power producers. These meters offer a wide versatility of feature and total performance. The meter can be the solution for transmission or distribution network. The modular, flexible ION technology architecture enables a simple, building block approach for customizing each meter to any application. Enable for the user acces to the analysis of energy, bill verification, cost allocation and more. And a number of power quality reporting. With 128 MB of memory to support data logs, alarms, RMS logging, historical logs, transient logs, event logs, revenue logs, GPS synch and Time of Use. The ability to timestamp events to +/-1 ms utilizing time synchronization methods that include SNTP, IRIG-B, GPS ASCII (RS485) and network time set function. Providing 1024 samples per cycle with Voltage inputs of 57-277 VAC L-N / 100-480 VAC L-L; Current inputs of 1 A, 2 A, and 5 A. Wide control power range of 120 to 277 VAC, 57 to 277 VAC L-N Onboard input output configurtion include 3 digital inputs, 2 pulse outputs and 4 relay outputs plus up to 3 dry contact sensing inputs. Multiple communication ports include: RS232/RS485, RS485, Infrared (ANSI type II) and Ethernet 10/100 BASE-T. Mechanical dimensions are 178 mm in height, 178 mm in width and 237 mm in depth, for a product weight of 7 kg. Certified for compliance report (EN 50160 ed. 4), and power quality measurement (IEC 61000-4-30 Class A). Socket form factor, setting available in 9S/29S/36S Base wiring 3-Element, 4-Wire / 2 1/2-Element, 4-Wire. With integrated display. Operating environment of -40 to +85C; Humidity rating of 5% to 95%; Altitude up to 3000 m. You can find the following accessories for ION8650: some input/output expanders, A-base adaptors and communication cable. Integration with EcoStruxure Power Operations software through multiple communication channels and protocols, Including Itron MV-90, Modbus, DNP, DLMS, IEC 61850. These meters give utilities the tools to manage complex energy supply contracts that include commitments to power quality.
Specifications
arrow2_down
Main
RangePowerLogic
Device short nameION8650A
Product or component typeRevenue and power quality meter
Complementary
Power quality analysisconforming to IEC 61000-4-15 flicker
magnitude harmonic up to the 50th
transient capture
conforming to EN 50160: ed. 4 compliance report
harmonic distortion
voltage sag and swell detection
waveform capture
programmablity (logic and math functions)
up to the 63rd harmonic
conforming to IEC 61000-4-30: class A power quality measurement
Device applicationInstrument transformer correction
Co-generation and IPP monitoring
Tariff metering
Equipment monitoring and control
Demand and power factor control
Load curtailment
Energy pulsing and totalisation
Type of measurementCurrent
Voltage
Frequency
Apparent power total
Power factor total
Apparent power per phase
Power factor per phase
Active power total
Active power per phase
Reactive power total
Reactive power per phase
supply voltage120...277 V AC 47...63 Hz
Network frequency50 Hz
[In] rated current2 A
5 A
1 A
type of network1P + N
3P
3P + N
Power consumption in VA24 VA
Maximum power consumption in VA33 VA
Display typeFSTN transflective LCD
Form designation9S 3-element 4
36S 2½-element 4
29S 2½-element 4
Sampling rate1024 samples/cycle
Measurement current0.001…24 A
input typeCurrent 0.01...20 A (impedance 0.05 Ohm)
Measurement voltage57…277 V AC phase to neutral
100…480 V AC phase to phase
Number of inputs3 digital 0.001...100 mA 30 V DC
Measurement accuracyCurrent 0.1 %
Voltage 0.1 %
Power 0.1 %
Power factor 0.1 %
Frequency 0.001 Hz
Energy 0.1 %
Accuracy classClass 0.2S energy conforming to IEC 62053-23
Class 0.2 energy conforming to ANSI C12.20
Class 0.2S energy conforming to IEC 62053-22
Number of outputs2 pulse
4 form C relay output
Communication port protocolDNP3 at 300...115200 bauds
ION at 300...115200 bauds
Ansi C12.18 at <= 19200 bauds
IEC 61850 ed. 2 at 10/100 Mbit/s
TCP/IP at 10/100 Mbit/s
DLMS at 300...115200 bauds
Modbus at 57600 bauds
DNP3 at 10/100 Mbit/s
ION at 10/100 Mbit/s
Modbus RTU, master/slave at 300...115200 bauds
Modbus TCP, master/slave at 10/100 Mbit/s
EtherGate
Communication port supportRJ45: ETHERNET
SUB-D 9: RS485/RS232
Terminal block: RS485
Infrared
Time synchronisation protocolIRIG-B
GPS: Truetime/Datum
Data recordingTime stamping
Data logs
Sag and swell logs
Revenue logs
Transient logs
GPS synchronisation
Event logs
Alarms
Harmonics logs
Historical logs
Transmission rate300...115200 bauds
<= 19200 bauds
57600 bauds
10/100 Mbit/s
Memory capacity128 MB
Web servicesPort addressing user designed
Robust security logs
Alarm notification by e-mail
Web server
Ethernet serviceSNMP-Traps and SYSLOG
Enable/disable Ethernet protocols
Enable/disable serial ports
Tamperproof of settingsHardware lock by jumper
Protected by access code
Compatibility codeION8650A
Environment
Electromagnetic compatibilityElectrostatic discharge immunity test conforming to IEC 61000-4-2
Conducted RF disturbances conforming to IEC 61000-4-6
Immunity to impulse waves conforming to IEC 61000-4-12
Electrical fast transient/burst immunity test conforming to IEC 61000-4-4
Susceptibility to electromagnetic fields conforming to IEC 61000-4-3
1.2/50 µs shock waves immunity test conforming to IEC 61000-4-5
Conducted and radiated emissions B conforming to CISPR 22
Mounting modeSocket-mounted
Mounting supportEnclosure door
Type of installationIndoor installation
Overvoltage categoryIII
IP degree of protectionIP65 front face:
IP51 back:
Relative humidity5…95 %
Pollution degree2
Ambient air temperature for operation-40…85 °C
Ambient air temperature for storage-40…85 °C
Operating altitude0...3000 m
StandardsANSI C12.1
IEC 62052-11
Width178 mm
Depth237 mm
Height178 mm
Net weight7 kg
Packing Units
Unit Type of Package 1PCE
Number of Units in Package 11
Package 1 Height26.0 cm
Package 1 Width28.0 cm
Package 1 Length44.0 cm
Package 1 Weight4.5 kg
Contractual warranty
Warranty18 months
arrow2_down
Schneider Electric aims to achieve Net Zero status by 2050 through supply chain partnerships, lower impact materials, and circularity via our ongoing “Use Better, Use Longer, Use Again” campaign to extend product lifetimes and recyclability.
Environmental footprint
Use Better
Materials and Substances
Use Again
Repack and remanufacture
Documents
arrow2_down
Software and Firmware
arrow2_down

Need more information? Check our technical FAQs!

Easily find answers to the most frequently asked questions.

  • Products Documentation
  • Software Downloads
  • Product Selector
  • Product Substitution and Replacement
  • Contact Support
  • Find our Offices
  • Need help? Start here
  • Where to buy
  • Careers
  • Company Profile
  • Newsroom
  • Investors
  • EcoStruxure
  • Job Search
  • Blog
  • Data Privacy
  • Cookies Policy
  • Terms of use
  • Change your cookie settings