RM22LA32MR
Range of product | Harmony Control Relays |
---|---|
Relay type | Level control relay |
Product or component type | Level control relay |
Relay name | RM22L |
Relay monitored parameters | Detection by resistive probes |
time delay | Adjustable 0.1...30 s, +/- 10 % of the full scale value Tt- time delay upon fault |
Switching capacity in VA | 2000 VA |
Minimum switching current | 10 mA at 5 V DC |
Maximum switching current | 8 A AC |
Utilisation category | AC-15 conforming to IEC 60947-5-1 DC-13 conforming to IEC 60947-5-1 AC-1 conforming to IEC 60947-4-1 DC-1 conforming to IEC 60947-4-1 |
Contacts type and composition | 2 C/O |
Maximum switching voltage | 250 V AC |
---|---|
[Un] rated nominal voltage | 24...240 V AC/DC 50/60 Hz, non self-powered |
Supply voltage limits | 20.4…264 V AC/DC |
power consumption | 1.5 W DC |
Output contacts | 2 C/O |
Nominal output current | 8 A |
delay at power up | 2.5 s 0.6 s |
Maximum electrode voltage | 12 V AC |
Maximum electrode current | 1 mA |
Repeat accuracy | +/- 2 % for time delay |
Measurement error | < 1 % over the whole range with voltage variation 0.05 %/°C with temperature variation |
Maximum cable distance between devices | 100 m between probe and delay |
Sensitivity scale | 0.25...5 kOhm LS (Low Sensitivity) 5...100 kOhm St (Standard Sensitivity) 50...1000 kOhm HS (High Sensitivity) |
Sensitivity adjustment | 5…100 % |
Maximum supply current for sensors | 1 mA |
Cable capacitance | 1 nF at HS (High Sensitivity) for probe cable 2.2 nF at St (Standard Sensitivity) for probe cable 4.7 nF at LS (Low Sensitivity) for probe cable |
Overvoltage category | III conforming to IEC 60664-1 |
Insulation | Between supply and measurement |
Connections - terminals | Screw terminals, 2 x 0.5...2 x 2.5 mm² (AWG 20...AWG 14) solid without cable end Screw terminals, 2 x 0.2...2 x 1.5 mm² (AWG 24...AWG 16) flexible with cable end Screw terminals, 1 x 0.5...1 x 3.3 mm² (AWG 20...AWG 12) solid without cable end Screw terminals, 1 x 0.2...1 x 2.5 mm² (AWG 24...AWG 14) flexible with cable end |
Tightening torque | 0.6…1 N.m conforming to IEC 60947-1 |
Housing material | Self-extinguishing plastic |
Mounting support | 35 mm DIN rail conforming to IEC 60715 |
Mounting position | Any position |
Electrical durability | 100000 cycles |
Mechanical durability | 10000000 cycles |
Contacts material | Cadmium free |
Measurement range | 0.25...1000 kOhm |
Safety reliability data | MTTFd = 182.6 years B10d = 170000 |
Width | 22.5 mm |
Control type | With test button |
Net weight | 0.11 kg |
Immunity to microbreaks | 100 ms DC 90 ms AC |
---|---|
Electromagnetic compatibility | Immunity for residential, commercial and light-industrial environments conforming to IEC 61000-6-1 Immunity for industrial environments conforming to IEC 61000-6-2 Emission standard for residential, commercial and light-industrial environments conforming to IEC 61000-6-3 Emission standard for industrial environments conforming to IEC 61000-6-4 Electrostatic discharge - test level: 6 kV level 3 (contact discharge) conforming to IEC 61000-4-2 Electrostatic discharge - test level: 8 kV level 3 (air discharge) conforming to IEC 61000-4-2 Radiated radio-frequency electromagnetic field immunity test - test level: 10 V/m level 3 conforming to IEC 61000-4-3 Electrical fast transient/burst immunity test - test level: 4 kV level 4 (direct) conforming to IEC 61000-4-4 Electrical fast transient/burst immunity test - test level: 2 kV level 4 (capacitive coupling) conforming to IEC 61000-4-4 Surge immunity test - test level: 4 kV level 4 (common mode) conforming to IEC 61000-4-5 Surge immunity test - test level: 2 kV level 4 (differential mode) conforming to IEC 61000-4-5 Conducted and radiated emissions class B group 1 conforming to CISPR 11 Conducted and radiated emissions class B conforming to CISPR 22 |
Standards | IEC 60255-1 |
Product certifications | UL RCM CSA GL CCC CE EAC |
Ambient air temperature for storage | -40…70 °C |
Relative humidity | 93…97 % at 25…55 °C conforming to IEC 60068-2-30 |
Vibration resistance | 0.075 mm (f= 10…58.1 Hz) not in operation conforming to IEC 60068-2-6 1 gn (f= 10…58.1 Hz) not in operation conforming to IEC 60068-2-6 0.035 mm (f= 58.1…150 Hz) in operation conforming to IEC 60068-2-6 0.5 gn (f= 58.1…150 Hz) in operation conforming to IEC 60068-2-6 |
Shock resistance | 15 gn (duration = 11 ms) for not in operation conforming to IEC 60068-2-27 5 gn (duration = 11 ms) for in operation conforming to IEC 60068-2-27 |
IP degree of protection | IP20 (terminals) conforming to IEC 60529 IP40 (housing) conforming to IEC 60529 IP50 (front panel) conforming to IEC 60529 |
Pollution degree | 3 conforming to IEC 60664-1 |
Dielectric test voltage | 2.5 kV, 1 min AC 50 Hz conforming to IEC 60255-27 |
Unit Type of Package 1 | PCE |
---|---|
Number of Units in Package 1 | 1 |
Package 1 Height | 2.6 cm |
Package 1 Width | 8.2 cm |
Package 1 Length | 9.5 cm |
Package 1 Weight | 122.0 g |
Unit Type of Package 2 | S02 |
Number of Units in Package 2 | 40 |
Package 2 Height | 15.0 cm |
Package 2 Width | 30.0 cm |
Package 2 Length | 40.0 cm |
Package 2 Weight | 5.492 kg |
Unit Type of Package 3 | P06 |
Number of Units in Package 3 | 640 |
Package 3 Height | 60.0 cm |
Package 3 Width | 80.0 cm |
Package 3 Length | 60.0 cm |
Package 3 Weight | 95.14 kg |
Wiring Diagram
A1,A2 : Supply voltage
Max : High level
Min : Low level
C : References or Tank earth electrode
11-14,12 : 1st C/O contact of output relay
21-24,22 : 2nd C/O contact of output relay
Wiring Diagram
A1,A2 : Supply voltage
Max : High level
Min : Low level
C : References or Tank earth electrode
11-14,12 : 1st C/O contact of output relay
Fill/Empty function
Un Supply voltage
(1) Min. level
(2) Max. level
11-12/11-14, 21-22/21-24 Output relay connections
Relay status: black color = energized.
Empty function T on
Empty function T off
Fill function T on
Fill function T off
Tt Time delay after crossing of threshold
Un Supply voltage
(1) Level threshold
11-12/11-14, 21-22/21-24 Output relay connections
Relay status: black color = energized.
Items usually bought together
Need more information? Check our technical FAQs!
Easily find answers to the most frequently asked questions.