Level control relay RM22-L - 24..240 V AC/DC - 2 C/O

RM22LA32MR

Environmental Data
Total lifecycle Carbon footprint
37
Use Better
Packaging made with recycled cardboard
information_stroke
Recycled cardboard content is minimum 70% (50% in US). Some orders may include non-recycled cardboard until stock runs out.
Yes
Use Again
Recyclability potential, in %
information_stroke
The calculation of the recyclability potential relies on the scenario "France - parts are shredded" of TR62635 considering all parts in the product and materials recyclability. We recognized that this may not always allow comparison with other competitor offers on the market and are waiting for a common standard to be published end of 2026.
18
Take-back
information_stroke
Whether the product has been included in a global take-back program. Some products are eligible in some geographies, please verify if it's available in your country.
No
Description
arrow2_down
This Harmony RM22-LA relay allows monitoring of liquid level control in 3-phase networks. This modular multi function 3-phase liquid level control relay is ideal for monitoring of electrical values in industrial and building control panels. It applies to a wide type of industrial automation applications such as hoisting, packaging, lifts, textile, water. It has one of market slim form-factors with 22.5mm width, allowing for a flexible and easy installation on DIN rail, using the same space as any modular 1-pole DIN device. It also offers a diagnostic button, sealable cover, simple and precise settings with screw trimmers. It provides automatic shutdown management and fault information to user for a quick fault identification and troubleshooting. multi function controller for wide choice selected in hard-wired logic automated systems, ideal for refurbishment of old installations without using a PLC.
Specifications
arrow2_down
Main
Range of productHarmony Control Relays
Relay typeLevel control relay
Product or component typeLevel control relay
Relay nameRM22L
Relay monitored parametersDetection by resistive probes
time delayAdjustable 0.1...30 s, +/- 10 % of the full scale value Tt- time delay upon fault
Switching capacity in VA2000 VA
Minimum switching current10 mA at 5 V DC
Maximum switching current8 A AC
Utilisation categoryAC-15 conforming to IEC 60947-5-1
DC-13 conforming to IEC 60947-5-1
AC-1 conforming to IEC 60947-4-1
DC-1 conforming to IEC 60947-4-1
Contacts type and composition2 C/O
Complementary
Maximum switching voltage250 V AC
[Un] rated nominal voltage24...240 V AC/DC 50/60 Hz, non self-powered
Supply voltage limits20.4…264 V AC/DC
power consumption1.5 W DC
Output contacts2 C/O
Nominal output current8 A
delay at power up2.5 s
0.6 s
Maximum electrode voltage12 V AC
Maximum electrode current1 mA
Repeat accuracy+/- 2 % for time delay
Measurement error< 1 % over the whole range with voltage variation
0.05 %/°C with temperature variation
Maximum cable distance between devices100 m between probe and delay
Sensitivity scale0.25...5 kOhm LS (Low Sensitivity)
5...100 kOhm St (Standard Sensitivity)
50...1000 kOhm HS (High Sensitivity)
Sensitivity adjustment5…100 %
Maximum supply current for sensors1 mA
Cable capacitance1 nF at HS (High Sensitivity) for probe cable
2.2 nF at St (Standard Sensitivity) for probe cable
4.7 nF at LS (Low Sensitivity) for probe cable
Overvoltage categoryIII conforming to IEC 60664-1
InsulationBetween supply and measurement
Connections - terminalsScrew terminals, 2 x 0.5...2 x 2.5 mm² (AWG 20...AWG 14) solid without cable end
Screw terminals, 2 x 0.2...2 x 1.5 mm² (AWG 24...AWG 16) flexible with cable end
Screw terminals, 1 x 0.5...1 x 3.3 mm² (AWG 20...AWG 12) solid without cable end
Screw terminals, 1 x 0.2...1 x 2.5 mm² (AWG 24...AWG 14) flexible with cable end
Tightening torque0.6…1 N.m conforming to IEC 60947-1
Housing materialSelf-extinguishing plastic
Mounting support35 mm DIN rail conforming to IEC 60715
Mounting positionAny position
Electrical durability100000 cycles
Mechanical durability10000000 cycles
Contacts materialCadmium free
Measurement range0.25...1000 kOhm
Safety reliability dataMTTFd = 182.6 years
B10d = 170000
Width22.5 mm
Control typeWith test button
Net weight0.11 kg
Environment
Immunity to microbreaks100 ms DC
90 ms AC
Electromagnetic compatibilityImmunity for residential, commercial and light-industrial environments conforming to IEC 61000-6-1
Immunity for industrial environments conforming to IEC 61000-6-2
Emission standard for residential, commercial and light-industrial environments conforming to IEC 61000-6-3
Emission standard for industrial environments conforming to IEC 61000-6-4
Electrostatic discharge - test level: 6 kV level 3 (contact discharge) conforming to IEC 61000-4-2
Electrostatic discharge - test level: 8 kV level 3 (air discharge) conforming to IEC 61000-4-2
Radiated radio-frequency electromagnetic field immunity test - test level: 10 V/m level 3 conforming to IEC 61000-4-3
Electrical fast transient/burst immunity test - test level: 4 kV level 4 (direct) conforming to IEC 61000-4-4
Electrical fast transient/burst immunity test - test level: 2 kV level 4 (capacitive coupling) conforming to IEC 61000-4-4
Surge immunity test - test level: 4 kV level 4 (common mode) conforming to IEC 61000-4-5
Surge immunity test - test level: 2 kV level 4 (differential mode) conforming to IEC 61000-4-5
Conducted and radiated emissions class B group 1 conforming to CISPR 11
Conducted and radiated emissions class B conforming to CISPR 22
StandardsIEC 60255-1
Product certificationsUL
RCM
CSA
GL
CCC
CE
EAC
Ambient air temperature for storage-40…70 °C
Relative humidity93…97 % at 25…55 °C conforming to IEC 60068-2-30
Vibration resistance0.075 mm (f= 10…58.1 Hz) not in operation conforming to IEC 60068-2-6
1 gn (f= 10…58.1 Hz) not in operation conforming to IEC 60068-2-6
0.035 mm (f= 58.1…150 Hz) in operation conforming to IEC 60068-2-6
0.5 gn (f= 58.1…150 Hz) in operation conforming to IEC 60068-2-6
Shock resistance15 gn (duration = 11 ms) for not in operation conforming to IEC 60068-2-27
5 gn (duration = 11 ms) for in operation conforming to IEC 60068-2-27
IP degree of protectionIP20 (terminals) conforming to IEC 60529
IP40 (housing) conforming to IEC 60529
IP50 (front panel) conforming to IEC 60529
Pollution degree3 conforming to IEC 60664-1
Dielectric test voltage2.5 kV, 1 min AC 50 Hz conforming to IEC 60255-27
Packing Units
Unit Type of Package 1PCE
Number of Units in Package 11
Package 1 Height2.6 cm
Package 1 Width8.2 cm
Package 1 Length9.5 cm
Package 1 Weight122.0 g
Unit Type of Package 2S02
Number of Units in Package 240
Package 2 Height15.0 cm
Package 2 Width30.0 cm
Package 2 Length40.0 cm
Package 2 Weight5.492 kg
Unit Type of Package 3P06
Number of Units in Package 3640
Package 3 Height60.0 cm
Package 3 Width80.0 cm
Package 3 Length60.0 cm
Package 3 Weight95.14 kg
arrow2_down
Schneider Electric aims to achieve Net Zero status by 2050 through supply chain partnerships, lower impact materials, and circularity via our ongoing “Use Better, Use Longer, Use Again” campaign to extend product lifetimes and recyclability.
Environmental footprint
Use Better
Materials and Substances
Use Again
Repack and remanufacture
Dimensions Drawings
arrow2_down
Dimensions



Mounting and Clearance
arrow2_down
Mounting and Clearance
Rail Mounting



Connections and Schema
arrow2_down
Level Control Relay

Wiring Diagram


A1,A2 : Supply voltage

Max : High level

Min : Low level

C : References or Tank earth electrode

11-14,12 : 1st C/O contact of output relay

21-24,22 : 2nd C/O contact of output relay


Control by Electrodes

Wiring Diagram


A1,A2 : Supply voltage

Max : High level

Min : Low level

C : References or Tank earth electrode

11-14,12 : 1st C/O contact of output relay


Technical Description
arrow2_down
Function Diagrams
Control of Two Levels

Fill/Empty function


Legend

Un Supply voltage

(1) Min. level

(2) Max. level

11-12/11-14, 21-22/21-24 Output relay connections

Relay status: black color = energized.

Control of One Level

Empty function T on


Empty function T off


Fill function T on


Fill function T off


Legend

Tt Time delay after crossing of threshold

Un Supply voltage

(1) Level threshold

11-12/11-14, 21-22/21-24 Output relay connections

Relay status: black color = energized.


Documents
arrow2_down
Software and Firmware
arrow2_down
arrow2_down

Need more information? Check our technical FAQs!

Easily find answers to the most frequently asked questions.

  • Products Documentation
  • Software Downloads
  • Product Selector
  • Product Substitution and Replacement
  • Contact Support
  • Find our Offices
  • Need help? Start here
  • Where to buy
  • Careers
  • Company Profile
  • Newsroom
  • Investors
  • EcoStruxure
  • Job Search
  • Blog
  • Data Privacy
  • Cookies Policy
  • Terms of use
  • Change your cookie settings