Issue Description:
After running analysis, attempting to access the report tab within the Data Quality (DQ) tab results in the page failing to load. Subsequently, the browser throws an out-of-memory exception error.
Product Line:
Power Advisor
Cause:
The root cause of the issue is the large size of certain sites, which includes thousands of devices. This leads to a memory crash in the browser when attempting to load one month of data.
Resolution:
Workaround to Generate the Data Quality (DQ) Report
If you encounter issues generating the DQ report due to a memory crash, follow these steps:
- Generate a DQ Report from a Smaller Site:
- Print a DQ report from a smaller, functioning site.
- Record the URL, e.g.,
https://ecostruxure-power-advisor.se.app/pa/Report?analysisResultId=26897&analysisCategoryId=2&isSummaryReport=false
2. Retrieve the Analysis Result ID from the Problematic Site:
- On the problematic site, open Chrome Developer Tools (F12).
- Run the analysis and navigate to the DQ tab.
- In the Network tab, search for 'analysisResultId' and record the value.
3. Access the DQ Report:
- Replace the analysisResultId in the URL from step 1 with the recorded value from step 2.
- Paste the updated URL into the browser while logged into the problematic site to access the DQ report.
https://ecostruxure-power-advisor.se.app/pa/Report?analysisResultId=<analysisResultId >&analysisCategoryId=2&isSummaryReport=false