Default Webpage Username & Password for PowerLogic Meters and/or their Ethernet Communication Card (ECC)

Issue:
In need of the default webpage username & password for PowerLogic meters with ethernet communication card.

Product Line:
ECC21 (ethernet communication card for CM3000 and CM4000 Series meters)
PM8ECC (ethernet communication card for PM800 Series meters)
PM5500 Series
PM8000 Series

Environment:
Webpage

Resolution


A power meter's webpage can be accessed by entering the meter's designated IP address into a web browser's address bar and logging in with the following default login information.

MeterPassword
CM3000 (ECC21)admin
CM4000 (ECC21)admin

Note: ECC21 for CM3000 and CM4000 does not request for username.


Note: To login to the web page of the CM3 and CM4, the Microsoft Silverlight extension must be installed on the web browser. If the webpage does not show menu items and you are using IE 11, please see ECC Web Page does not show menu items. | Schneider Electric USA

MeterUsernamePassword
PM800 (PM8ECC)AdministratorGateway
PM8000User10




PM5500 default webpage credentials:

Configuration areaUsernameDefault password/passcode
Display passcode-0000 (zero)
For Firmware versions:
  • PM5560 / PM5562 / PM5563 / PM5580 meter models: 2.9.9 and earlier
  • PM5570 / PM5660 / PM5760 meter models: 3.2.9 and earlier
  • PM5561 meter models: 10.9.9 and earlier
Webpages and FTP
  • Web master
  • Product master
user1
user2
pass1
pass2
For firmware versions:
  • PM5560 / PM5562 / PM5563 / PM5580 meter models: 4.0.0 and above
  • PM5570 / PM5660 / PM5760 meter models: 6.0.0 and above
  • PM5561 meter models: 12.0.0 and above
Webpages and FTP/FTPSAdministratorMAC address which is unique for each meter
Note: Enter the MAC address of the meter without colon in capital letters. (For example: if the MAC address of the meter is 00:80:f4:02:14:38, then password is 0080F4021438)
WebpagesGuestPowerlogic@1
Note: Forced to change the default password for system security the first time you log in.



More Information


Note
: the following information applies to the following:

  • PM5560 / PM5562 / PM5563 / PM5580 meter models with firmware 2.9.9 and earlier
  • PM5570 / PM5660 / PM5760 meter models: 3.2.9 and earlier
  • PM5561 meter models: 10.9.9 and earlier

PM5000 series only has web pages for the PM5500 series, and the PM5500 series has two default users with different privileges, Web Master and Product Master.
See Different User Groups for PM5500 series meter and their access level | Schneider Electric USA for more information about account privileges.
The default usernames for the PM5500, user1 and user2, cannot be changed or deleted, but their passwords can be.
The PM5300 does not have a web page even though it has Ethernet communications.

Refer to PM8000 default IP address, username, and password | Schneider Electric USA for more information about the PM8000 username and password.
Please see What are the default User name and Password for the EGX, Link, and Com'X gateway devices? | Schneider Electric USA for information on the default login credentials for web interface on Communication devices i.e. Com'X, Link150, and EGXs

施耐德電機Taiwan

探索更多
產品:
系列:
探索更多
產品:
系列:
  • 產品文檔
  • 軟體下載
  • 產品選型工具
  • 產品替代和替換
  • 幫助和聯絡中心
  • 尋找我們的辦公室
  • 取得報價
  • 施耐德電機社群
  • 人才招募
  • 公司簡介
  • 舉報不當行為
  • 無障礙
  • 新聞中心
  • 投資者
  • 專業洞察
  • 台灣施耐德電機學院
  • 綠色影響力落差調查
  • Schneider Go Green 2025
  • 隱私政策
  • Cookie通告
  • 使用條款
  • Change your cookie settings