Наші бренди

Impact-Company-Logo-English Black-01-177x54

Вітаємо на веб-сайті Schneider Electric

Ласкаво просимо на наш веб-сайт.
		
Чим ми можемо вам допомогти сьогодні?
How can I upload a project from an HMI using Vijeo Designer programming software?

Issue:
Uploading a project from an HMI using Vijeo Designer programming software.


Product Line:
Vijeo Designer, HMIGTO, HMISTU, HMIGTU, HMISTO5, XBTGT


Resolution:
1) Launch Vijeo Designer.
2) Right-click on Vijeo Manager and select "Upload Editor Project".
Upload

3) Select the method by which you wish to upload the project. You can upload via Ethernet, Serial, or USB. If you wish to upload via Ethernet, enter the IP address of the HMI.
Upload

If this FAQ did not solve your issue, you can chat with us at chat with us or e-mail us at customer.services@se.com to create a case with our Technical Support Team.

If you are not located in North America, please contact your local Customer Care Center for assistance:

Support | Schneider Electric Global (se.com)


Schneider Electric Україна

Досліджуйте більше
Серія:
Досліджуйте більше
Серія:
  • Документація Продукції
  • Завантаження ПЗ
  • Інструмент вибору продукту
  • Заміна та заміщення продукту
  • Контактний центр із надання довідки
  • Знайти наші представництва"
  • Де купити
  • Спільнота Schneider Electric
  • Вакансії
  • Профіль компанії
  • Повідомити про проступок
  • Спеціальні можливості
  • Новини
  • Інвестори
  • EcoStruxure
  • Вакансії Пошук
  • Блог
  • Політика конфіденційності
  • Сповіщення про файли cookie
  • Умови користування
  • Change your cookie settings