Issue:
Operating temperature range for the Altistart 22
Product Line:
ATS22, Altistart 22
Environment:
All models, all serial numbers.
Cause:
high or low ambient temperatures.
Resolution:
The standard current ratings for the ATS22 is based on an ambient temperature of 40C (104F).
The minimum operating temperature is -10C (14F). The maximum operating temperature is 60C (140F).
When operating above 40C (104F), the softstart needs to be derated by 2.2% for every degree Celsius above 40C (104F).
For example: ATS22D32S6U is 32A rated. For an ambient temperature of 50C (122F), derating is 22% (2.2 x 10). The 32A softstart rating becomes 24.96A (32A x 0.78 = 24.96).
Operating temperature range for the Altistart 22
Product Line:
ATS22, Altistart 22
Environment:
All models, all serial numbers.
Cause:
high or low ambient temperatures.
Resolution:
The standard current ratings for the ATS22 is based on an ambient temperature of 40C (104F).
The minimum operating temperature is -10C (14F). The maximum operating temperature is 60C (140F).
When operating above 40C (104F), the softstart needs to be derated by 2.2% for every degree Celsius above 40C (104F).
For example: ATS22D32S6U is 32A rated. For an ambient temperature of 50C (122F), derating is 22% (2.2 x 10). The 32A softstart rating becomes 24.96A (32A x 0.78 = 24.96).
Опубліковано для: Schneider Electric Україна


Потрібна допомога?
Інструмент вибору продукту
Швидко та легко знаходьте потрібні продукти й допоміжне обладнання для своїх завдань.
Розрахувати вартість
Ставте свої запитання щодо продажів онлайн, і з вами зв’яжеться фахівець
Де придбати?
Зручний пошук найближчого дистриб’ютора, магазина або спеціалізованого партнера Schneider Electric у вашому регіоні.
Довідковий центр
Знайдіть усі необхідні ресурси для підтримки в одному місці.