Difference between a neutral position limit switch and a two-stage limit switch
Issue:
What is the difference between a neutral position limit switch and a two-stage limit switch?
Product Line:
Limit Switches - GIC Product
Environment:
US Product
Cause:
Resolution:
Understanding the process is essential for Limit switch selection and knowing the differences between the 2 types, vital in the correct selction.
Neutral position switches have two different sets of contacts in which one set of contacts changes state when the head is actuated one way and a second set of contacts will change state if the head is actuated in the opposite direction. Both sets of contacts reset when the head actuates back to center.
Two stage switches also have independent contacts. One set of contacts changes state if the head moves in one direction, and with further head travel movement in the same direction, the other set of contacts will also change state.
What is the difference between a neutral position limit switch and a two-stage limit switch?
Product Line:
Limit Switches - GIC Product
Environment:
US Product
Cause:
Resolution:
Understanding the process is essential for Limit switch selection and knowing the differences between the 2 types, vital in the correct selction.
Neutral position switches have two different sets of contacts in which one set of contacts changes state when the head is actuated one way and a second set of contacts will change state if the head is actuated in the opposite direction. Both sets of contacts reset when the head actuates back to center.
Two stage switches also have independent contacts. One set of contacts changes state if the head moves in one direction, and with further head travel movement in the same direction, the other set of contacts will also change state.
Опубліковано для: Schneider Electric Україна
Досліджуйте більше
Серія:
Досліджуйте більше
Серія:
Потрібна допомога?
Почніть тут!
Знайдіть відповіді зараз. Шукайте рішення самостійно або зверніться до нашого експерта.
Звернутися до служби підтримки
Якщо вам потрібна допомога, додаткова інформація чи технічна підтримка або ви хочете подати скаргу, зв’яжіться з нашою командою з обслуговування клієнтів.
Де придбати?
Зручний пошук найближчого дистриб’ютора, магазина або спеціалізованого партнера Schneider Electric у вашому регіоні.
Переглянути відповіді на поширені запитання
Отримайте необхідну інформацію, переглянувши відповіді на поширені запитання за відповідними темами.