Наші бренди

Вітаємо на веб-сайті Schneider Electric

Ласкаво просимо на наш веб-сайт.
		
Чим ми можемо вам допомогти сьогодні?
Error while installing SQL Server 2012 - Access Denied

Issue
During the installation of SQL Server 2012 an error which states
"Access to the path 'C:\Program Files\Microsoft SQL Server\110\License Terms\SQLServerDenaliCTP_License_EVAL_1033.rtf' is denied."  is displayed.
SQL error

Product

PME 7.2

PME 8.x

PME 9.0


Environment

SQL Server 2012

Cause
Access to the file identified within the error message is secured as a Read-Only file.

Resolution
To rectify this error and continue with the installation, browse to the path "C:\Program Files\Microsoft SQL Server\110\License Terms\" and change the property
of file "SQLServerDenaliCTP_License_EVAL_1033.rtf" to remove "Read-Only".  Click on "Retry" button and the installation process will resume.

Please Note: SQL 2012 Has reached end of life support.

https://learn.microsoft.com/en-us/lifecycle/announcements/sql-server-2012-windows-server-2012-2012-r2-end-of-support

Schneider Electric Україна

Досліджуйте більше
Продукт:
Досліджуйте більше
Продукт:
  • Документація Продукції
  • Завантаження ПЗ
  • Інструмент вибору продукту
  • Заміна та заміщення продукту
  • Контактний центр із надання довідки
  • Знайти наші представництва
  • Де купити
  • Спільнота Schneider Electric
  • Запит цінової пропозиції
  • Вакансії
  • Профіль компанії
  • Повідомити про проступок
  • Спеціальні можливості
  • Новини
  • Інвестори
  • EcoStruxure
  • Вакансії Пошук
  • Блог
  • Політика конфіденційності
  • Сповіщення про файли cookie
  • Умови користування
  • Change your cookie settings