Cannot see load values in Connexium Network Manager
Issue:
Cannot see load values in Connexium Network Manager 'Load' window.
Product:
Connexium Network Manager 2.0
Environment:
Windows 10
Resolution:
The Connexium Network Manager 'Load' window does not show any traffic load between the ports of two Ethernet devices.
The reasons for not being able to see a load value between the Ethernet ports of two different devices (i.e., Connexium TCSESM switch and NOE77101) could be either:
Cannot see load values in Connexium Network Manager 'Load' window.
Product:
Connexium Network Manager 2.0
Environment:
Windows 10
Resolution:
The Connexium Network Manager 'Load' window does not show any traffic load between the ports of two Ethernet devices.
The reasons for not being able to see a load value between the Ethernet ports of two different devices (i.e., Connexium TCSESM switch and NOE77101) could be either:
- Improper configuration.
- Incorrect VLAN has been selected.
- No traffic load on the network segment between the ports
- Check the load values of the connection between the server and the Connexium TCESEM switch port by opening the web interface.
- Right click on the switch icon and selecting 'Web Interface'
- Navigate to "Diagnostics --> Ports --> Utilization" and see whether there is load on the port.
- Go back to the Connexium Network Manager 'Map' window.
- Double click on the link between the two Ethernet ports to see what amount of traffic is display. (Note: The traffic is normally split between incoming and outgoing load.) to open the load window.
- Compare the displayed values with the values in Connexium Network Manager 'Load' window with the values found in the Connexium TCSESM Web Server 'Utilization' window.
- Determine if the values are matched between the two windows.
- If the values are lower than expected, then there is a probability that there is no traffic being transmitted between the ports.
Опубліковано для: Schneider Electric Україна
Досліджуйте більше
Серія:
Досліджуйте більше
Серія:
Потрібна допомога?
Почніть тут!
Знайдіть відповіді зараз. Шукайте рішення самостійно або зверніться до нашого експерта.
Звернутися до служби підтримки
Якщо вам потрібна допомога, додаткова інформація чи технічна підтримка або ви хочете подати скаргу, зв’яжіться з нашою командою з обслуговування клієнтів.
Де придбати?
Зручний пошук найближчого дистриб’ютора, магазина або спеціалізованого партнера Schneider Electric у вашому регіоні.
Переглянути відповіді на поширені запитання
Отримайте необхідну інформацію, переглянувши відповіді на поширені запитання за відповідними темами.