Чим ми можемо вам допомогти сьогодні?

Vijeo Designer Runtime Manager always launches with "Welcome to Vijeo Designer Trial Edition"

Issue: Vijeo Designer Runtime Manager always auto-starts and displays the dialog "Welcome to Vijeo Designer Trial Edition"

Product Line: Vijeo Designer Runtime for iPC/Generic PC

Resolution: This dialog will always appear (even if you have registered the software) when you are running under a user account (ie non-administrator). To stop this message from appearing, you will need to log out of the user account, login as an Administrator and press the "Start/Yes" button on the dialog box "Welcome to Vijeo Designer Trial Edition". This will set a registry key to stop the dialog box from appearing again. Once this is set, you can log back in as the user account. The application will start as expected.

Schneider Electric Україна

  • Документація Продукції
  • Завантаження ПЗ
  • Інструмент вибору продукту
  • Заміна та заміщення продукту
  • Контактний центр із надання довідки
  • Знайти наші представництва
  • Де купити
  • Спільнота Schneider Electric
  • Запит цінової пропозиції
  • Вакансії
  • Профіль компанії
  • Повідомити про проступок
  • Спеціальні можливості
  • Новини
  • Інвестори
  • EcoStruxure
  • Вакансії Пошук
  • Блог
  • Загальні умови ведення бізнесу
  • Політика конфіденційності
  • Сповіщення про файли cookie
  • Умови користування
  • Change your cookie settings