Чим ми можемо вам допомогти сьогодні?

How to set the time and date on an iPC running Vijeo Designer Runtime

Issue:
How to set the time and date on an iPC running Vijeo Designer Runtime

Product Line:
Magelis iPC running Vijeo Designer Runtime (all versions)

Resolution:
In order to properly set the time and date within the Vijeo Designer Runtime, you must be sure that the application is launched as Administrator. In other words, right-click on the Vijeo Designer Runtime icon and select "Run as Administrator". If you do not do this, the changes will not take effect. If you require to run the application automatically at login, please create a scheduled Windows Task to launch VIjeo Designer Runtime when a user logs in. Also, ensure to check the check box to run with the highest privileges in the properties of the task.

Schneider Electric Україна

Досліджуйте більше
Серія:
Досліджуйте більше
Серія:
  • Документація Продукції
  • Завантаження ПЗ
  • Інструмент вибору продукту
  • Заміна та заміщення продукту
  • Контактний центр із надання довідки
  • Знайти наші представництва
  • Де купити
  • Спільнота Schneider Electric
  • Запит цінової пропозиції
  • Вакансії
  • Профіль компанії
  • Повідомити про проступок
  • Спеціальні можливості
  • Новини
  • Інвестори
  • EcoStruxure
  • Вакансії Пошук
  • Блог
  • Політика конфіденційності
  • Сповіщення про файли cookie
  • Умови користування
  • Change your cookie settings