Наші бренди

Impact-Company-Logo-English Black-01-177x54

Вітаємо на веб-сайті Schneider Electric

Ласкаво просимо на наш веб-сайт.
		
Чим ми можемо вам допомогти сьогодні?
How to select replacement for XPSBCE, XPSBF, XPSVC and XPSDMB

Article available in these languages: Czech, Dutch

XPSBCE is replaced by XPSUS 24V
XPSBCE change

Commercial ReferenceReplacement Commercial Reference
XPSBCE3110CXPSUS12AC
XPSBCE3110PXPSUS12AP


Replacement/substitution according to the terminal connector:
XPSBCE change

Wiring Two-Hand Control* (24VAC/DC) diagram XPSBCE & XPSUS
XPSBCE change

XPSBCE is replaced by XPSUS - 115V/230V

XPSBCE change

Commercial ReferenceReplacement Commercial Reference
XPSBCE3410CXPSUS32AC
XPSBCE3410PXPSUS32AP
XPSBCE3710CXPSUS32AC
XPSBCE3710PXPSUS32AP


Replacement/substitution according to the terminal connector:
XPSBCE change

Wiring Two-Hand Control* (115/230VAC) diagram XPSBCE & XPSUS
XPSBCE change

XPSBF is replaced by XPSUS
XPSBF change

Commercial ReferenceReplacement Commercial Reference
XPSBF1132XPSUS12AP
XPSBF1132PXPSUS12AP


Replacement/substitution according to the terminal connector:
XPSBF change
Wiring Two-Hand Control* (24VAC/DC) diagram XPSBF & XPSUS

XPSBF change
XPSVC is replaced by XPSUS
XPSVC change

Commercial ReferenceReplacement Commercial Reference
XPSVC1132XPSUS12AP
XPSVC1132PXPSUS12AP


Replacement/substitution according to the terminal connector:
XPSVC change
Wiring Enabling Switch diagram XPSVC & XPSUAF
XPSVC change
XPSDMB is replaced by XPSUS
XPSDMB change

Commercial ReferenceReplacement Commercial Reference
XPSDMB1132XPSUS12AP
XPSDMB1132PXPSUS12AP


Replacement/substitution according to the terminal connector:
XPSDMB change
Wiring Coded Magnetic Switches diagram XPSDMB & XPSUS
XPSDMB change

XPSDMB change
XPSUS change

CAUTION

The information provided in this documentation contains general descriptions and/or technical characteristics of the performance of the products contained herein. This documentation is not intended as a substitute for and is not to be used for determining suitability or reliability of these products for specific user applications. It is the duty of any such user or integrator to perform the appropriate and complete risk analysis, evaluation and testing of the products with respect to the relevant specific application or use thereof. Neither Schneider Electric nor any of its affiliates or subsidiaries shall be responsible or liable for misuse of the information contained herein. If you have any suggestions for improvements or amendments or have found errors in this publication, please notify us.

You agree not to reproduce, other than for your own personal, noncommercial use, all or part of this document on any medium whatsoever without permission of Schneider Electric, given in writing. You also agree not to establish any hypertext links to this document or its content. Schneider Electric does not grant any right or license for the personal and noncommercial use of the document or its content, except for a non-exclusive license to consult it on an "as is" basis, at your own risk. All other rights are reserved.

All pertinent state, regional, and local safety regulations must be observed when installing and using this product. For reasons of safety and to help ensure compliance with documented system data, only the manufacturer should perform repairs to components.

When devices are used for applications with technical safety requirements, the relevant instructions must be followed.

Failure to use Schneider Electric software or approved software with our hardware products may result in injury, harm, or improper operating results.

Failure to observe this information can result in injury or equipment damage.

© 2021 Schneider Electric. All rights reserved.

Schneider Electric Україна

Досліджуйте більше
Продукт:
Досліджуйте більше
Продукт:
  • Документація Продукції
  • Завантаження ПЗ
  • Інструмент вибору продукту
  • Заміна та заміщення продукту
  • Контактний центр із надання довідки
  • Знайти наші представництва
  • Де купити
  • Спільнота Schneider Electric
  • Запит цінової пропозиції
  • Вакансії
  • Профіль компанії
  • Повідомити про проступок
  • Спеціальні можливості
  • Новини
  • Інвестори
  • EcoStruxure
  • Вакансії Пошук
  • Блог
  • Політика конфіденційності
  • Сповіщення про файли cookie
  • Умови користування
  • Change your cookie settings