Наші бренди

Impact-Company-Logo-English Black-01-177x54

Вітаємо на веб-сайті Schneider Electric

Ласкаво просимо на наш веб-сайт.
		
Чим ми можемо вам допомогти сьогодні?
License Manager Integrity check failed

Issue:

When launching or installing License Manager an integrity check is reported and it does not open. The C:\Users\yourusername\AppData\Local\Temp\License Manager_reg.log shows signature problems on certain dlls.

Follow the steps below to update any certificates for .dll files that are listed as a problem in the License Manager_reg.log file.

1 - Run the following command(as Admin) to download the latest certificates in an SST file(requires internet, then you can transfer the file to the offline VM):

certutil.exe -generateSSTFromWU roots.sst

2- Open Powershell as admin and run the following commands: (You can open the roots.sst and install one by one the certificates that you require)

$sstStore = ( Get-ChildItem -Path <em>CertPath</em>\roots.sst)

$sstStore | Import-Certificate -CertStoreLocation Cert:\LocalMachine\Root

Example:

257920_IMG

Schneider Electric Україна

Досліджуйте більше
Серія:
Досліджуйте більше
Серія:
  • Документація Продукції
  • Завантаження ПЗ
  • Інструмент вибору продукту
  • Заміна та заміщення продукту
  • Контактний центр із надання довідки
  • Знайти наші представництва
  • Де купити
  • Спільнота Schneider Electric
  • Запит цінової пропозиції
  • Вакансії
  • Профіль компанії
  • Повідомити про проступок
  • Спеціальні можливості
  • Новини
  • Інвестори
  • EcoStruxure
  • Вакансії Пошук
  • Блог
  • Політика конфіденційності
  • Сповіщення про файли cookie
  • Умови користування
  • Change your cookie settings