Чим ми можемо вам допомогти сьогодні?
How to Configure Microsoft Edge to Accept Insecure/Self-Assigned SSL Certificates
Issue
Microsoft Edge will not allow you manually access the PME web application due to the self-assigned certificate, giving the error message "It looks like the webpage might be having issues, or it may be moved permanently to a new address.
"ERR_SSL_KEY_USAGE_INCOMPATIBLE".

Product Line
Power Monitoring Expert 2020
Power Monitoring Expert 2021
Power Monitoring Expert 2022
Power Monitoring Expert 2023
Environment
Power Monitoring Expert Web Applications
Microsoft Edge
Cause
By default, Microsoft Edge does not allow you to access the PME webpage while SSL is enabled, and HTTPS is required causing the webpage to no longer be accessible
Resolution
Note: This also allows you to reload legacy web pages
The following steps detail how to enable compatibility mode in Microsoft Edge
Microsoft Edge will not allow you manually access the PME web application due to the self-assigned certificate, giving the error message "It looks like the webpage might be having issues, or it may be moved permanently to a new address.
"ERR_SSL_KEY_USAGE_INCOMPATIBLE".
Product Line
Power Monitoring Expert 2020
Power Monitoring Expert 2021
Power Monitoring Expert 2022
Power Monitoring Expert 2023
Environment
Power Monitoring Expert Web Applications
Microsoft Edge
Cause
By default, Microsoft Edge does not allow you to access the PME webpage while SSL is enabled, and HTTPS is required causing the webpage to no longer be accessible
Resolution
Note: This also allows you to reload legacy web pages
The following steps detail how to enable compatibility mode in Microsoft Edge
- Open Microsoft Edge
- Select the ellipses in the top right corner of the web browser and open the Settings option
- Use the navigation windows on the left side to navigate to the "Appearance" page
- Scroll down on the main page to the "(IE Mode)" setting, and select the link "allow sites to be reloaded in Internet Explorer mode"
- A new tab will be opened with the "Internet Explorer compatibility" settings. Select the following option:
- Always - Let Internet Explorer open sites in Microsoft Edge
- Select the "Add" button, then type the URL https://Localhost/web and select "Add"
- Allow - Allow sites to be reloaded in Internet Explorer Mode (IE mode)
- Restart - For this setting change to take effect, restart your browser
- Close and open the Microsoft Edge browser application to finalize the changes
- Once restarted, select the ellipses in the top right corner of the web browser and open the Settings option
- Use the navigation windows on the left side of the web browser's windows to navigate to the "Appearance" page
- Scroll down on the main page to the "(IE Mode)" setting, and turn the slider to on
- Navigate to the PME Web Applications page
- Select the internet explorer mode button at the top right of the browser window
- The browser page will be reloaded, and a small window will open in the top left with a couple of options
- Select the "Open this page in Compatibility view" and "Open this page in Internet Explorer mode next time" to ensure the window will be opened in IE Mode in the future
- Select the "Open this page in Compatibility view" and "Open this page in Internet Explorer mode next time" to ensure the window will be opened in IE Mode in the future
Опубліковано для: Schneider Electric Україна
Досліджуйте більше
Продукт:
Досліджуйте більше
Продукт:
Потрібна допомога?
Почніть тут!
Знайдіть відповіді зараз. Шукайте рішення самостійно або зверніться до нашого експерта.
Звернутися до служби підтримки
Якщо вам потрібна допомога, додаткова інформація чи технічна підтримка або ви хочете подати скаргу, зв’яжіться з нашою командою з обслуговування клієнтів.
Де придбати?
Зручний пошук найближчого дистриб’ютора, магазина або спеціалізованого партнера Schneider Electric у вашому регіоні.
Переглянути відповіді на поширені запитання
Отримайте необхідну інформацію, переглянувши відповіді на поширені запитання за відповідними темами.