PowerChute Network Advanced contains a JRE version impacted by CVE-2026-114938

Issue:

PowerChute Network Advanced contains a JRE version that may be impacted by CVE-2026-114938

Product:

PowerChute Network Advanced (PCNA)

Versions: 1.0.0 and 1.0.1

Environment:

All supported Windows Operating Systems

Cause:

Vulnerability in the Oracle Java SE, Oracle GraalVM for JDK, and Oracle GraalVM Enterprise Edition products of Oracle Java SE (component: Compiler).

For more information, see: https://nvd.nist.gov/vuln/detail/cve-2026-114938

Solution:

Per https://calif.io/java4shell#poc - PCNA is not impacted, but the issue can be mitigated by adding "-XX:-UseBASE64Intrinsics" as a startup flag in PCNA.xml

To mitigate the issue:

1. Stop the PCNA service. Open a command prompt as an administrator and enter net stop pcna.
2. Edit C:\Program Files\Schneider Electric\PowerChute Network Advanced\PCNA.xml using a text editor.
3. Add "-XX:-UseBASE64Intrinsics" to the arguments list, as shown below.
<arguments>-XX:-UseBASE64Intrinsics -Dspring.profiles.active=test -Dpf4j.pluginsDir="ºSE%\plugins" -jar "ºSE%\pcna.jar"</arguments>
4. Save PCNA.xml and re-start the service net start pcna.

Schneider Electric Україна

Досліджуйте більше

Досліджуйте більше

Потрібна допомога?

Почніть тут!

Знайдіть відповіді зараз. Шукайте рішення самостійно або зверніться до нашого експерта.

Звернутися до служби підтримки

Якщо вам потрібна допомога, додаткова інформація чи технічна підтримка або ви хочете подати скаргу, зв’яжіться з нашою командою з обслуговування клієнтів.

Де придбати?

Зручний пошук найближчого дистриб’ютора, магазина або спеціалізованого партнера Schneider Electric у вашому регіоні.

Переглянути відповіді на поширені запитання

Отримайте необхідну інформацію, переглянувши відповіді на поширені запитання за відповідними темами.