Our Brands

Welcome to the Schneider Electric Website

Welcome to our website.
		
How can we help you today?
What causes the error: " Attempted IO operation (write) on READ-ONLY " when I go onto Vijeo Designer Webgate?

Issue:
The cause of the error: " Attempted IO operation (write) on READ-ONLY "  when logged into Vijeo Designer Webgate


Product Line:
Vijeo Designer


Resolution:
You will get this error either due to the variables are not set for 'read/write' for data sharing. Or you are accessing Webgate without security.
If you do not enable Webgate security, you will only have read only access. Create a Security group and User and the error should go away.

If this FAQ did not solve your issue, you can chat with us at chat with us or e-mail us at customer.services@se.com to create a case with our Technical Support Team.

If you are not located in North America, please contact your local Customer Care Center for assistance:
Support | Schneider Electric Global (se.com)

Schneider Electric UK

Explore more
Range:
Users group

Discuss this topic with experts

Visit our community and get advice from experts and peers on this topic and more
Explore more
Range:
  • Products Documentation
  • Software Downloads
  • Product Selector
  • Product Substitution and Replacement
  • Help and contact centre
  • Where to buy
  • Get a Quote
  • Find our Offices
  • Schneider Electric Community
  • Careers
  • Company Profile
  • Report a misconduct
  • Accessibility
  • Newsroom
  • Investors
  • EcoStruxure
  • Job Search
  • Blog
  • Privacy Policy
  • Cookie Notice
  • Terms of use
  • Change your cookie settings