Our Brands

Welcome to the Schneider Electric Website

Welcome to our website.
		
How can we help you today?
How to use Lexium32 limit switches for TwinCAT NC-homing (Lexium32-EtherCAT)

Goals and Symptoms

How to use Lexium32 limit switches for TwinCAT NC-homing (Lexium32-EtherCAT)

Causes and Fixes

Before the MC_Home will be started, it is required to disable the limit switches in the drive temporary by object 3006:11h. The state of the digital IO can be mapped into the PDO and linked into the PLC-program (for using it on input bCalibrationCAM on MC_Home)

Schneider Electric UK

Users group

Discuss this topic with experts

Visit our community and get advice from experts and peers on this topic and more
  • Products Documentation
  • Software Downloads
  • Product Selector
  • Product Substitution and Replacement
  • Help and contact centre
  • Where to buy
  • Get a Quote
  • Find our Offices
  • Schneider Electric Community
  • Careers
  • Company Profile
  • Report a misconduct
  • Accessibility
  • Newsroom
  • Investors
  • EcoStruxure
  • Job Search
  • Blog
  • Privacy Policy
  • Cookie Notice
  • Terms of use
  • Change your cookie settings