Our Brands

Welcome to the Schneider Electric Website

Welcome to our website.
		
How can we help you today?
How to Restore Backup Database from SQL 2005 to SQL 2012
Issue:
When trying to restore a SQL 2005 database in SQL 2012, the Database Restore will give the following error: “The database was backed up on a sever running version 8.002065. That version is incompatible with this server, which is running version 11.00.3000.”

Product Line:
Power Monitoring Expert v7.2.2

Environment:
SQL Server Management Studio

Cause:
It is not possible to restore a SQL 2005 database directly to SQL 2012.

Resolution:
1) Restore the SQL 2005 database backup on a SQL Server 2008 system.
2) Take a backup of the database from the SQL 2008 system.
3) Restore the SQL 2008 database backup on the SQL 2012 system.

Schneider Electric UK

Explore more
Range:
Users group

Discuss this topic with experts

Visit our community and get advice from experts and peers on this topic and more
Explore more
Range:
  • Products Documentation
  • Software Downloads
  • Product Selector
  • Product Substitution and Replacement
  • Help and contact centre
  • Where to buy
  • Get a Quote
  • Find our Offices
  • Schneider Electric Community
  • Careers
  • Company Profile
  • Report a misconduct
  • Accessibility
  • Newsroom
  • Investors
  • EcoStruxure
  • Job Search
  • Blog
  • Privacy Policy
  • Cookie Notice
  • Terms of use
  • Change your cookie settings