How do you access a bit in a word in a M221 controller using Machine Expert Basic (former SoMachine Basic) software?
The syntax to access a bit in a word is %MWx:X where X is the offset of the bit.
Example: to turn on bit 10 of %MW20 you can use a coil with address %MW20:X10
If this FAQ did not solve your issue, you can chat with us at chat with us or e-mail us at customer.services@se.com to create a case with our Technical Support Team.