How can we help you today?
Does Schneider-Electric have a regenerated VFD that will return back the voltage to the line?
Issue:
Schneider-Electric return back the voltage to the line.
Product Line:
ATV930
Environment:
Regen drives
Cause:
Product Selection
Resolution:
1) ATV980 is a series of regenerative drives:
https://www.se.com/ww/en/product-range/63124-altivar-process-atv900/914058402-drive-systems?N=201182946&Nr=AND(P_visibility:1,product.siteId:700002,OR(product.catalogId:catalog50001))&Nrpp=10&parent-subcategory-id=86129#tabs
2) There are Altivar Regenerative Units : ATVRU75N4, ATVRD15N4 - they can evacuate energy back to the supply lines.
They can work with ATV320/340, ATV6xx/9xx, drives.
https://www.se.com/ww/en/product/ATVRD15N4/regenerative-unit---15-kw---for-altivar-variable-speed-drive#search?langType=englishUTF8
https://www.se.com/ww/en/product/ATVRU75N4/regenerative-unit---7,5-kw---for-altivar-variable-speed-drive#search?langType=englishUTF8
https://www.se.com/ww/en/download/document/NVE88423/
https://www.se.com/ww/en/download/document/NVE94856/
3) For ATV71 use Altivar AFE (Active Front END)
https://www.se.com/ww/en/product-range/7555-altivar-afe-(active-front-end)?N=3936592704&parent-category-id=2900&filter=business-1-industrial-automation-and-control
Schneider-Electric return back the voltage to the line.
Product Line:
ATV930
Environment:
Regen drives
Cause:
Product Selection
Resolution:
1) ATV980 is a series of regenerative drives:
https://www.se.com/ww/en/product-range/63124-altivar-process-atv900/914058402-drive-systems?N=201182946&Nr=AND(P_visibility:1,product.siteId:700002,OR(product.catalogId:catalog50001))&Nrpp=10&parent-subcategory-id=86129#tabs
2) There are Altivar Regenerative Units : ATVRU75N4, ATVRD15N4 - they can evacuate energy back to the supply lines.
They can work with ATV320/340, ATV6xx/9xx, drives.
https://www.se.com/ww/en/product/ATVRD15N4/regenerative-unit---15-kw---for-altivar-variable-speed-drive#search?langType=englishUTF8
https://www.se.com/ww/en/product/ATVRU75N4/regenerative-unit---7,5-kw---for-altivar-variable-speed-drive#search?langType=englishUTF8
https://www.se.com/ww/en/download/document/NVE88423/
https://www.se.com/ww/en/download/document/NVE94856/
3) For ATV71 use Altivar AFE (Active Front END)
https://www.se.com/ww/en/product-range/7555-altivar-afe-(active-front-end)?N=3936592704&parent-category-id=2900&filter=business-1-industrial-automation-and-control
Released for: Schneider Electric UK
Explore more
Range:
Explore more
Range:
Need help?
Product Selector
Quickly and easily find the right products and accessories for your applications.
Get a Quote
Start your sales inquiry online and an expert will connect with you.
Where to buy?
Easily find the nearest Schneider Electric distributor in your location.
Help Centre
Find support resources for all your needs, in one place.