On an Altivar Process Drive, how can I take a screenshot using the remote keypad and download to PC?

Issue:
Could not find how to do print screen on Altivar Process drives.

Product Line:
Altivar Process Drive (ATV630, ATV930, ATV650, ATV950, ATV660, ATV960, ATV680, ATV980)

Environment:
All models,

Cause:
N/A

Resolution:
A screenshot can be taken from the remote keypad by pressing both the F1 and F4 keys at the same time.
To upload the keypad screenshot, use the mini USB port on the keypad to connect to the PC.
See the attached file below.
The USB port has 2 main functions:
  • Download screenshot files
  • Upload program files (e.g. languages)
On the PC, open up the Keypad Folder and go to the Print Screen folder (labeled PRTSCR).
Transfer the file to a PC folder.

Note:
It is not possible to connect both a Computer and the Drive to the keypad at the same time.

Schneider Electric UK

Attachment(s)
VW3A1111 screenshot.pdf [188.37 KB]
Explore more
Range:
Users group

Discuss this topic with experts

Visit our community and get advice from experts and peers on this topic and more
Explore more
Range:
  • Products Documentation
  • Software Downloads
  • Product Selector
  • Product Substitution and Replacement
  • Help and contact centre
  • Where to buy
  • Get a Quote
  • Find our Offices
  • Schneider Electric Community
  • Careers
  • Company Profile
  • Report a misconduct
  • Accessibility
  • Newsroom
  • Investors
  • EcoStruxure
  • Job Search
  • Blog
  • General Terms of Business
  • Privacy Policy
  • Cookie Notice
  • Terms of use
  • Change your cookie settings
  • Preference Center