{}

Our Brands

Impact-Company-Logo-English Black-01-177x54

Welcome to the Schneider Electric Website

Welcome to our website.

Search FAQs

Is it possible to control Lexium 28 via Modbus communication?

Full Modbus control is not implemented into Lexium 28 design.

It's possible to read and write parameters via Modbus, but it is not possible to fully control the drive via the Modbus channel because there are no
modbus objects available on LXM28 for the "ControlWord" or for the "ModesOfOperation".

However, it is also possible to force inputs of LXM28A via Modbus.
Therefore it is possible to control Lexium 28 via Modbus for simple motion control.

rev 8-16-18

Schneider Electric UK

Explore more
Range:
Lexium 28 & Motors
Explore more
Range:
Lexium 28 & Motors
Users group

Discuss this topic with experts

Visit our Community for first-hand insights from experts and peers on this topic and more.