Can all contact blocks be used for the 30mm range joysticks? [Video]
Question:
Can all contact blocks be used for the 30mm range joysticks?
Product String Reference:
- Top Level > Product Category > Industry > Industry Control & Drives > Control, Relays & Sign > Diameter 30.
- Top Level > PR_Product_OPS_Structure > Pushbuttons, Switches, Pilot Lights and Joysticks > 30mm Push Buttons > Harmony 30mm 9001K Metal Push Buttons
Objective:
The objective of this video is to provide an in-depth analysis of contact blocks and their application.
Product Line:
IDSIG - CONTROL, RELAYS & SIGN.
Environment:
N/A
Resolution:
When used in conjunction with a Harmony range push button, the:
- Combination N/O + N/C, N/C opens and N/O closes
- N/C contact opens when push button is depressed
- N/O contact closes when push button is depressed
When used in conjunction with the 30mm range joystick application.
- Combination N/O + N/C will stay open so that it is neither open nor closed
- N/C contact is open
- N/O contact is open
- Combination N/O + N/C will close at different positions of the joystick handle.
- N/C will close
- N/O will close
As such, these contacts do not act in the same way for a joystick as they do for the Harmony range push button application.
Released for: Schneider Electric UK
Explore more
Range:
Explore more
Range:
Need help?
Product Selector
Quickly and easily find the right products and accessories for your applications.
Get a Quote
Start your sales inquiry online and an expert will connect with you.
Where to buy?
Easily find the nearest Schneider Electric distributor in your location.
Help Centre
Find support resources for all your needs, in one place.