How can we help you today?
CANopen telegram. What is the content of CANopen data frame and its length?
CANopen data frame consists of :
SOF = start of frame (1 bit)
Arbitration field = 12 or 32 bits depending on whether 11 or 29 bit identifier is used (feature of the device)
Control field = 6 bits
Data field depends on mapping. Process data object can carry max 8 bytes. If each variable takes 2bytes then max content of 4 variables in data filed is possible.
CRC = control redundancy check (16 bits)
ACK = acknowledge (2 bits)
EOF = end of frame + intermission (7+3 bits)
Total: 47 bits + data filed (derived from number of variables mapped and their length).
Released for: Schneider Electric UK
Explore more
Range:
Explore more
Range:
Need help?
Product Selector
Quickly and easily find the right products and accessories for your applications.
Get a Quote
Start your sales inquiry online and an expert will connect with you.
Where to buy?
Easily find the nearest Schneider Electric distributor in your location.
Help Centre
Find support resources for all your needs, in one place.