How can we help you today?

How do I connect an HMIDM Modular Display touch-screen to a PC as a monitor?

Issue
How do I connect an HMIDM Modular Display touch-screen to a PC as a monitor?
The panel does not seem to have a DVI, DisplayPort, or HDMI socket built into it.

Product Line
Magelis HMIDM Modular Display (HMIDM7421, HMIDM7521, HMIDM9521, HMIDMA521, HMIDM6421, HMIDM6521)
Magelis Modular Box PC

Resolution
The Magelis HMIDM Modular Display touch-screens  do not have DVI, DisplayPort, or HDMI sockets built into them. They are designed to be connected directly to Magelis HMIBM Modular Box PC CPU/Motherboard modules via a proprietary connector for display.

To connect this line of Modular Display via Display Port to a PC, a display adapter with Reference Part Number HMIDADP11 must be purchased.
https://www.se.com/ww/en/product/HMIDADP11/display-adaptor-dp-for-hmidm/

Note: The HMIDADP11 can also display video to a Magelis Modular Display from a Magelis HMIBM Modular Box PC via Ethernet remotely.

If the PC does not have a DisplayPort video output, DVI output from the PC can be converted with a DVI to DisplayPort adapter with Reference Part Number HMIYADDPDVI11.
https://www.se.com/us/en/product/HMIYADDPDVI11/adaptor-from-display-port-to-dvi-d/

Schneider Electric UK

Explore more

Discuss this topic with experts

Visit our community and get advice from experts and peers on this topic and more

Explore more

Need help?

Product Selector

Quickly and easily find the right products and accessories for your applications.

Get a Quote

Start your sales inquiry online and an expert will connect with you.

Where to buy?

Easily find the nearest Schneider Electric distributor in your location.

Help Centre

Find support resources for all your needs, in one place.