Our Brands

Welcome to the Schneider Electric Website

Welcome to our website.
		
How can we help you today?
When trying to install SoMachine v4.3, the the SoMachine Configuration Manager Installation Tab window is blank

Issue
When trying to install SoMachine v4.3, the the SoMachine Configuration Manager Installation Tab window is blank and the left side menu items like "Install New Version " is grayed-out. What do I do?

Product Line
SoMachine v4.x

Environment
PLC Configuration Software Installation for Windows

Cause
The Configuration Manager is not pointed to the location of the installation DVD or disc .ISO image file.

Resolution
Follow the steps below:

  1. Ensure that you have either (a) the Installation DVD in the DVD-ROM Drive or (b) the path of the .ISO image file of the SoMachine Installation disc.
  2. In SoMachine Configuration Manager, click on the "Settings" Tab
  3. Under "Known Paths for Installation Media on Hard Drive", click on the [+] button.
  4. Select the path of the DVD-ROM or the .ISO file.
  5. Click back on the "Install" tab.

SoMachine Configuration Manager Settings - choose installation media folder
The screen should now be populated with the installable components of SoMachine and the left menu should no longer be grayed-out.
Click the "Install New Version" menu item to start the installation.


Schneider Electric UK

Explore more
Range:
Users group

Discuss this topic with experts

Visit our community and get advice from experts and peers on this topic and more
Explore more
Range:
  • Products Documentation
  • Software Downloads
  • Product Selector
  • Product Substitution and Replacement
  • Help and contact centre
  • Where to buy
  • Get a Quote
  • Find our Offices
  • Schneider Electric Community
  • Careers
  • Company Profile
  • Report a misconduct
  • Accessibility
  • Newsroom
  • Investors
  • EcoStruxure
  • Job Search
  • Blog
  • Privacy Policy
  • Cookie Notice
  • Terms of use
  • Change your cookie settings