How to Obtain All SQL Server Jobs Details
Issue
How to obtain all the details of all SQL Jobs created on a SQL server instance.
Product Line
Power Monitoring Expert 7.2.2
Power Monitoring Expert 8.2
Power Monitoring Expert 9.0
Power Monitoring Expert 2020
Power Monitoring Expert 2021
Power Monitoring Expert 2022
Power Monitoring Expert 2023
Power Monitoring Expert 2024
Environment
Microsoft SQL Server
SQL Server Management Studios
Cause
For daily monitoring purposes or for troubleshooting SQL job issues, obtaining information about the SQL jobs via a single query can be a very useful and time-saving alternative method.
Resolution
*Warning: Irreparable database damage can occur. This procedure should only be performed by users familiar with SQL Server Management Studio. Databases should be backed up prior to performing this procedure.*
This query will provide the SQL Server job details for all jobs present. It will provide the job name, job status, Last run date of the job & job execution status (failed or successful)
It may also be modified to add or change the fields reported as per the requirement.
To obtain these job details, log into SQL Server Management Studio and run the attached SQL script (SQL_Job_Details.sql).
Alternatively, execute the query(s) below:
Use msdb
go
select distinct j.Name as "Job Name", --j.job_id,
case j.enabled
when 1 then 'Enable'
when 0 then 'Disable'
end as "Job Status", jh.run_date as [Last_Run_Date(YY-MM-DD)] ,
case jh.run_status
when 0 then 'Failed'
when 1 then 'Successful'
when 2 then 'Retry'
when 3 then 'Cancelled'
when 4 then 'In Progress'
end as Job_Execution_Status
from sysJobHistory jh, sysJobs j
where j.job_id = jh.job_id and jh.run_date =
(select max(hi.run_date) from sysJobHistory hi where jh.job_id = hi.job_id )-- to get latest date Released for: Schneider Electric UK
Attachment(s)
Explore more
Product:
Explore more
Product:
Need help?
Product Selector
Quickly and easily find the right products and accessories for your applications.
Get a Quote
Start your sales inquiry online and an expert will connect with you.
Where to buy?
Easily find the nearest Schneider Electric distributor in your location.
Help Centre
Find support resources for all your needs, in one place.