How can we help you today?

Java web pages for the Modbus Plus Proxy module returns a blank window.

If you try to open a web page that contains a Java applet, a blank window could get returned.

This will occur if the IP address for the Java security exception is not defined.

To make an exception for the IP address of the Modbus Plus Proxy module,
  • Open the Control Panel for Windows
dfdv

  • Open the Java control panel
  • Click on 'Security'.
  • Click on 'Edit Site List.
svfv

  • Enter the IP address (i.e., http://172.23.13.217) of the Modbus Plus Proxy module.
Note:  In addition to the IP address of the module, the Modbus TCP/IP port 502 must also be defined in
the list (i.e., http://172.23.13.217:502)
vfs

Schneider Electric UK

Explore more
Product:
Users group

Discuss this topic with experts

Visit our community and get advice from experts and peers on this topic and more
Explore more
Product:
  • Products Documentation
  • Software Downloads
  • Product Selector
  • Product Substitution and Replacement
  • Help and contact centre
  • Where to buy
  • Get a Quote
  • Find our Offices
  • Schneider Electric Community
  • Careers
  • Company Profile
  • Report a misconduct
  • Accessibility
  • Newsroom
  • Investors
  • EcoStruxure
  • Job Search
  • Blog
  • General Terms of Business
  • Privacy Policy
  • Cookie Notice
  • Terms of use
  • Change your cookie settings
  • Preference Center