Our Brands

Welcome to the Schneider Electric Website

Welcome to our website.
		
How can we help you today?
Which devices need to be installed externally on the EVlink Home charger?

Article available in these languages: German

The EVlink Home charger must be protected at least by an overcurrent circuit breaker plus a minimum 30mA earth leakage Type A protection according to IEC 62851-1 and IEC 60364-7-722
Depending on your product, Mx or MNx auxiliary protection is also mandatory in some countries (refer to the user manuel included in the packaging).

Schneider Electric UK

Explore more
Range:
Users group

Discuss this topic with experts

Visit our community and get advice from experts and peers on this topic and more
Explore more
Range:
  • Products Documentation
  • Software Downloads
  • Product Selector
  • Product Substitution and Replacement
  • Help and contact centre
  • Where to buy
  • Get a Quote
  • Find our Offices
  • Schneider Electric Community
  • Careers
  • Company Profile
  • Report a misconduct
  • Accessibility
  • Newsroom
  • Investors
  • EcoStruxure
  • Job Search
  • Blog
  • Privacy Policy
  • Cookie Notice
  • Terms of use
  • Change your cookie settings