When using VW3A1111 with either ATV320 or ATV630, the print screen feature stops working
You can use the VW3A1111 to capture an image (jpg) of whatever is shown on screen at the time by using the plain black coloured buttons just below the screen.
If you press button number 1 on the left and button number 4 on the right at the same time, the screen will flash red for a moment and the screen will be saved on the keypad in a folder called PRTSCN.
You can access these on a computer by connecting via micro USB cable. The keypad will appear as a thumb drive and you can access the folder for PRTSCN directly from there.
You should note that you can only store 20 pictures on the keypad at one time. If you have any storage issues when you have reached this limit, you must delete the PRTSCN folder completely to enable the storage of new files. The next time that you save a screen shot, a new folder will be created automatically.