What is the Replacement Battery for my Back-UPS in Europe?

Question:

What is the Replacement Battery for my Back-UPS in Europe?

Answer:

The below table lists Back-UPS models and the replacement battery for each model.

Note: Certain Back-UPS models are designed with batteries that are not user-replaceable. Battery replacement in these units may expose live electrical components. To ensure safety, replacement must only be performed by qualified service personnel.

Product LineModelReplace Battery SKUNote
Back-UPSBE500G2-FRRBC46User Replaceable Battery
Back-UPSBE500G2-GRRBC46User Replaceable Battery
Back-UPSBE500G2-ITRBC46User Replaceable Battery
Back-UPSBE500G2-UKRBC46User Replaceable Battery
Back-UPSBE650G2-CPAPCRBC110User Replaceable Battery
Back-UPSBE650G2-FRAPCRBC110User Replaceable Battery
Back-UPSBE650G2-GRAPCRBC110User Replaceable Battery
Back-UPSBE650G2-ITAPCRBC110User Replaceable Battery
Back-UPSBE650G2-SPAPCRBC110User Replaceable Battery
Back-UPSBE650G2-UKAPCRBC110User Replaceable Battery
Back-UPSBE850G2-CPRBC17User Replaceable Battery
Back-UPSBE850G2-FRRBC17User Replaceable Battery
Back-UPSBE850G2-ITRBC17User Replaceable Battery
Back-UPSBE850G2-RSRBC17User Replaceable Battery
Back-UPSBE850G2-SPRBC17User Replaceable Battery
Back-UPSBE850G2-UKRBC17User Replaceable Battery
Back-UPSBE1050G2-FRRBC17User Replaceable Battery
Back-UPSBE1050G2-GRRBC17User Replaceable Battery
Back-UPSBE1050G2-ITRBC17User Replaceable Battery
Back-UPSBE1050G2-UKRBC17User Replaceable Battery
Back-UPSBK325IRBC2User Replaceable Battery
Back-UPSBK500EIRBC2User Replaceable Battery
Back-UPSBK650EIRBC17User Replaceable Battery
Back-UPSBX500MIAPCRBC110Battery not user replaceable
Back-UPSBX750MIRBC17Battery not user replaceable
Back-UPSBX750MI-FRRBC17Battery not user replaceable
Back-UPSBX750MI-GRRBC17Battery not user replaceable
Back-UPSBX950MIRBC17Battery not user replaceable
Back-UPSBX950MI-FRRBC17Battery not user replaceable
Back-UPSBX950MI-GRRBC17Battery not user replaceable
Back-UPSBX1200MIAPCRBC175Battery not user replaceable
Back-UPSBX1200MI-FRAPCRBC175Battery not user replaceable
Back-UPSBX1200MI-GRAPCRBC175Battery not user replaceable
Back-UPSBX1600MIAPCRBC176Battery not user replaceable
Back-UPSBX1600MI-FRAPCRBC176Battery not user replaceable
Back-UPSBX1600MI-GRAPCRBC176Battery not user replaceable
Back-UPSBX2200MIAPCRBC177Battery not user replaceable
Back-UPSBX2200MI-FRAPCRBC177Battery not user replaceable
Back-UPSBX2200MI-GRAPCRBC177Battery not user replaceable
Back-UPSBXS500MIAPCRBC110Battery not user replaceable
Back-UPSBXS750MIRBC17Battery not user replaceable
Back-UPSBXS750MI-GRRBC17Battery not user replaceable
Back-UPSBXS950MIRBC17Battery not user replaceable
Back-UPSBXS950MI-GRRBC17Battery not user replaceable
Back-UPSBXS1200MIAPCRBC175Battery not user replaceable
Back-UPSBXS1200MI-GRAPCRBC175Battery not user replaceable
Back-UPS ProBGM2200-GRAPCRBC216User Replaceable Battery
Back-UPS ProBGM2200-UKAPCRBC216User Replaceable Battery
Back-UPS ProBGM2200B-UKAPCRBC216User Replaceable Battery
Back-UPS ProBGM2200B-GRAPCRBC216User Replaceable Battery
Back-UPS ProBR650MIAPCRBC110User Replaceable Battery
Back-UPS ProBR900G-FRAPCRBC123User Replaceable Battery
Back-UPS ProBR900G-GRAPCRBC123User Replaceable Battery
Back-UPS ProBR900MIAPCRBC164User Replaceable Battery
Back-UPS ProBR1200G-FRAPCRBC124User Replaceable Battery
Back-UPS ProBR1200G-GRAPCRBC124User Replaceable Battery
Back-UPS ProBR1200SIAPCRBC161User Replaceable Battery
Back-UPS ProBR1300MIAPCRBC165User Replaceable Battery
Back-UPS ProBR1500G-FRAPCRBC124User Replaceable Battery
Back-UPS ProBR1500G-GRAPCRBC124User Replaceable Battery
Back-UPS ProBR1500GIAPCRBC124User Replaceable Battery
Back-UPS ProBR1600MIAPCRBC166User Replaceable Battery
Back-UPS ProBR1600SIAPCRBC163User Replaceable Battery

Schneider Electric UK

Discuss this topic with experts

Visit our community and get advice from experts and peers on this topic and more

Explore more

Need help?

Product Selector

Quickly and easily find the right products and accessories for your applications.

Get a Quote

Start your sales inquiry online and an expert will connect with you.

Where to buy?

Easily find the nearest Schneider Electric distributor in your location.

Help Centre

Find support resources for all your needs, in one place.