SCADAPack Configuration software and Corresponding Controllers
- SCADAPack devices are configured and programmed using a variety of specialized software tools. Each tool serves a unique purpose, from ladder logic programming to advanced configuration and diagnostics.
Primary Software Platforms
-
SCADAPack Workbench
A comprehensive development environment supporting multiple programming languages including C++, ISaGRAF (IEC 61131-3), and Relay Ladder Logic. -
SCADAPack Configurator
Used for configuring SCADAPack 330, 334 models, and SCADAPack 32 with ISAGRAF firmware. -
SCADAPack E Configurator
Tailored for SCADAPack E-series devices, offering enhanced configuration capabilities. -
Telepace Studio
A programming tool supporting Relay Ladder Logic, widely used for SCADAPack 300 series and SCADAPack 32. -
Remote Connect and Control Expert
Advanced tools for remote diagnostics, configuration, and control of SCADAPackx70 RTUs. -
Target 3 & Target 5
These refer to specific firmware environments used for programming and deploying applications on SCADAPack devices.
The tableshowing which SCADA Pack software tools support which hardware models.
| Software Tool | Supported SCADAPack Models Supported SCADAPack Models | |||||||||||||||||||
| SCADAPack workbench | Target 3 | SCADAPack 100 | SCADAPack 314 | SCADAPack 32(5601) | SCADAPack 32(5604) | SCADAPack 32(5606) | SCADAPack 32P | SCADAPack 330 | SCADAPack 334 | SCADAPack 350 | SCADAPack 350V1 | SCADAPack 357 | SCADAPack 357V1 | SCADAPack 4203 DR | SCADAPack 4203 DS | |||||
| Target 5 | SCADAPack 300E | SCADAPack 500E | SCADAPack ES/ER | |||||||||||||||||
| SCADAPack Configurator | SCADAPack 100.1024K | SCADAPack 314 | SCADAPack 32 | SCADAPack 32P | SCADAPack 330 | SCADAPack 334 | SCADAPack 350 | SCADAPack 4203 DR | SCADAPack 4203 DS | |||||||||||
| SCADAPack E Configurator | SCADAPack 500E | SCADAPack 535E | SCADAPack ES Model A | SCADAPack ES Model B | SCADAPack ES Model C | SCADAPack ER-P600 | SCADAPack ER-P620 | SCADAPack 312E | SCADAPack 313E | SCADAPack 314E | SCADAPack 300E | SCADAPack 333E | SCADAPack 334E | SCADAPack 337E | SCADAPack 350E | SCADAPack 357E | ||||
| Telepace Studio | Micro 16 | SCADAPack | SCADAPack Light | SCADAPack Plus | SCADAPack 100.256K | SCADAPack 100.1024K | SCADAPack LP | SCADAPack 314 | SCADAPack 32 | SCADAPack 32P | SCADAPack 330 | SCADAPack 334 | SCADAPack 350 | SCADAPack 4203 DR | SCADAPack 4203 DS | SCADAPack 4202 DR | SCADAPack 4202 DS | FlowStation 100 | NOC60 | |
| RemoteConnect and Control Expert | SCADAPack 474 | SCADAPack 474i | SCADAPack 470 | SCADAPack 470i | SCADAPack 570 | SCADAPack 574 | SCADAPack 575 | |||||||||||||
Note:
- Both the Serck 386 and 586 eNETs used the E Series Configurator and E Series Firmware (hence will work with either ISaGRAF for E Series, or SCADAPack Workbench for E Series).
- Serck 586 was re-named as SCADAPack ES at one point.
Links for the software:
Please refer article Where Can I Find Download Links for Remote Operations Software? | Schneider Electric Canada for the download links
Released for: Schneider Electric UK
Explore more
Range:
Explore more
Range:
Need help?
Product Selector
Quickly and easily find the right products and accessories for your applications.
Get a Quote
Start your sales inquiry online and an expert will connect with you.
Where to buy?
Easily find the nearest Schneider Electric distributor in your location.
Help Centre
Find support resources for all your needs, in one place.