What are the replacement parts for an H267AWK, series E4 heavy duty safety switch?
Issue:
Repair parts
Product Line:
HD Safety Switch
Resolution:
The parts listed here are the only field replaceable parts on the H267AWK, series E4:
---Line Base Assembly - 4401119750 (qty 1 per phase, includes Lug, Arc Suppressor not included)
---Line Base Insulating Plug - 4401133901 (qty 3 per phase)
---Base Mounting Screw - 4020600901 (qty 3 per phase)
---Line Base Phase Barrier - 4401119501 (qty 1)
---Arc Suppressor - 4051270850 (qty 1 per phase)
---Arc Suppressor Mounting Screws - 2140910321 (qty 3)
---Load Base Assembly - 4401120050 (qty 1 per phase, Lug not included)
---Lug - 4405005302 (qty 1 per phase)
---Base Mounting Screw - 4020600901 (qty 2 per phase)
---Lug Mounting Nut - 2342702400 (qty 1 per wire)
---Crossbar Insulator Kit - 4051275250 (note: the metal crossbar is not replaceable)
---Handle Assembly - 4401141350 (qty 1, includes Handle Knob)
---Handle Assembly Mounting Bolt - 2140122242 (qty 2)
---Handle Assembly Lock Washer - 2370200221 (qty 2)
---Red Knob - 4052085701 (qty 1)
---Black Knob - 4052085702 (qty 1)
---Rivet - 2410184441 (qty 2)
---Door Thumb Screw - 4405043401 (qty 3)
---Door Thumb Screw Retainer - 4405049001 (qty 3)
---Bolt = 2140128481
---Nut = 2342702800
---Washer = 2360100280
Repair parts
Product Line:
HD Safety Switch
Resolution:
The parts listed here are the only field replaceable parts on the H267AWK, series E4:
---Line Base Assembly - 4401119750 (qty 1 per phase, includes Lug, Arc Suppressor not included)
---Line Base Insulating Plug - 4401133901 (qty 3 per phase)
---Base Mounting Screw - 4020600901 (qty 3 per phase)
---Line Base Phase Barrier - 4401119501 (qty 1)
---Arc Suppressor - 4051270850 (qty 1 per phase)
---Arc Suppressor Mounting Screws - 2140910321 (qty 3)
---Load Base Assembly - 4401120050 (qty 1 per phase, Lug not included)
---Lug - 4405005302 (qty 1 per phase)
---Base Mounting Screw - 4020600901 (qty 2 per phase)
---Lug Mounting Nut - 2342702400 (qty 1 per wire)
---Crossbar Insulator Kit - 4051275250 (note: the metal crossbar is not replaceable)
---Handle Assembly - 4401141350 (qty 1, includes Handle Knob)
---Handle Assembly Mounting Bolt - 2140122242 (qty 2)
---Handle Assembly Lock Washer - 2370200221 (qty 2)
---Red Knob - 4052085701 (qty 1)
---Black Knob - 4052085702 (qty 1)
---Rivet - 2410184441 (qty 2)
---Door Thumb Screw - 4405043401 (qty 3)
---Door Thumb Screw Retainer - 4405049001 (qty 3)
---Bolt = 2140128481
---Nut = 2342702800
---Washer = 2360100280
Released for: Schneider Electric USA
Explore more
Range:
Explore more
Range:
Need help?
Product Selector
Quickly and easily find the right products and accessories for your applications.
Get a Quote
Start your sales inquiry online and an expert will connect with you.
Where to buy?
Easily find the nearest Schneider Electric distributor in your location.
Help Center
Find support resources for all your needs, in one place.