What are the repair parts for the H322DS, series F6? (may be shown as F06)
Issue:
Repair parts
Product Line:
HD SS
Resolution:
The repair parts for the H322DS, series F6 (F06) are as follows. No other parts are available.
Line Base Assembly - 4056642050 (arc suppressor not included)
Load Base Assembly - 4056002550K
Line & Load Base mounting screw - 4020516001 (3 for line and 2 for load)
Arc Suppressor Assembly - HAS0610F (includes arc suppressor and mounting screw)
Lug Assembly - 4025101652 (per lug)
Lug Keps Nut - 2342501701 (per lug)
Mechanism Assembly - 4056610750 (NOTE: handle coupling, cover interlock defeat coupling, and lockplate gaskets may also need replacing)
Handle Coupling - 4056699850
Cover Interlock Defeat Coupling - 4056699750
Handle Assembly - 4056699450 (also recommend replacing lockplate gaskets)
Lockplate - 4056693201 (also recommend replacing lockplate gaskets)
Lockplate Gasket - 4050322802 (2 required) - Obsolete. Replaced with 4050322803
Lockplate mounting screw - 2194918121 (2 required)
Ground Lug - 4025101652 (2 required)
Ground Lug Mounting Screw - 4020513503
Fuse Pullers - FPK03 (1 required)
Repair parts
Product Line:
HD SS
Resolution:
The repair parts for the H322DS, series F6 (F06) are as follows. No other parts are available.
Line Base Assembly - 4056642050 (arc suppressor not included)
Load Base Assembly - 4056002550K
Line & Load Base mounting screw - 4020516001 (3 for line and 2 for load)
Arc Suppressor Assembly - HAS0610F (includes arc suppressor and mounting screw)
Lug Assembly - 4025101652 (per lug)
Lug Keps Nut - 2342501701 (per lug)
Mechanism Assembly - 4056610750 (NOTE: handle coupling, cover interlock defeat coupling, and lockplate gaskets may also need replacing)
Handle Coupling - 4056699850
Cover Interlock Defeat Coupling - 4056699750
Handle Assembly - 4056699450 (also recommend replacing lockplate gaskets)
Lockplate - 4056693201 (also recommend replacing lockplate gaskets)
Lockplate Gasket - 4050322802 (2 required) - Obsolete. Replaced with 4050322803
Lockplate mounting screw - 2194918121 (2 required)
Ground Lug - 4025101652 (2 required)
Ground Lug Mounting Screw - 4020513503
Fuse Pullers - FPK03 (1 required)
Released for: Schneider Electric USA
Explore more
Product:
Explore more
Product:
Need help?
Product Selector
Quickly and easily find the right products and accessories for your applications.
Get a Quote
Start your sales inquiry online and an expert will connect with you.
Where to buy?
Easily find the nearest Schneider Electric distributor in your location.
Help Center
Find support resources for all your needs, in one place.