How can we help you today?

Why did ZB4BS84430 Replace ZB4BS5430?

Issue:
Difference between trigger action and non-trigger action pushbuttons.

Product Line:
Harmony XB4/XB5 Push Buttons

Environment:
Push Buttons and Operator Interface

Resolution:
Trigger action pushbuttons are impossible to partially engage the contacts.  The trigger action causes the operator to snap over from one state to the other once engaged past a point of no return.  For safety applications and emergency off/stop applications, this is the preferred method.  In general, trigger actuated pushbuttons are 5mm longer than the non-trigger action counterparts. PDF copy of original letter sent to customer base attached.

Schneider Electric USA

Attachment(s)
Emergency Stop Evolutions.pdf [55 KB]
Explore more
Range:
Users group

Discuss this topic with experts

Visit our community and get advice from experts and peers on this topic and more
Explore more
Range:
  • Help Center
  • Contact Sales
  • Find our Offices
  • Where to Buy
  • Tech Support: 877-342-5173
  • Careers
  • Company Profile
  • Investors
  • Newsroom
  • Report a Misconduct
  • Product Documentation
  • Software and Firmware
  • Product Selector
  • Product Replacement
  • DigestPLUS Online Catalog
  • Industries
  • Partners
  • Schneider Electric Community
  • Events
  • Privacy Policy
  • Cookie Notice
  • Terms of use
  • Change your cookie settings